FLAME APPEARANCE

Flames from the pilot, front and rear burner should be visually checked as soon as the heater is installed.

In addition, periodically check the flames visually during operation.

CHECKING THE PILOT FLAME

The pilot flame must always be present when the heater is in operation. It should just touch the top of the thermocouple tip for natural. Refer to Figure 18 for correct pilot flame.

If the pilot flame does not touch the thermocouple, then the main burner cannot function reliably. Refer to Figure 19 for incorrect shape of pilot flame.

MILLI-VOLT CONTROL

Thermocouple

for Natural

Thermocouple

for LP

Figure 18 - Correct Appearance of Pilot Flame

Thermocouple

for Natural

Thermocouple

for LP

Figure 19 - Incorrect Appearance of Pilot Flame