CLEARANCES and HEIGHT REQUIREMENTS
Heat resistant material (minimum requirements) with wooden mantel or other combustible projection:
To install the heater with a wooden mantel, shelf or other combustible projection above, first measure the heat resistant material shown in Figure 6, the refer to Table B.
Hood
8" or More of Heat Resistant Material
Heater in
Fireplace or
Firebox
Figure 6 - Measuring Heat Resistant Material for Mantel
| HEAT RESISTANT |
|
|
| MATERIAL | REQUIREMENTS FOR SAFE INSTALLATION WITH WOODEN MANTEL, |
|
| MEASUREMENT | SHELF OR OTHER COMBUSTIBLE PROJECTION |
|
|
|
|
|
| 12" or more | Hood not required. Observe profile (side elevations) shown in Figure 7, page 14. |
|
|
|
|
|
| 8" to less than 12" | Install hood and observe profiles shown in Figure 8, page 14; OR extend heat resistant |
|
|
| material to at least 12" and observe profiles shown in Figure 7, page 14. |
|
|
|
|
|
| Less than 8" | Extend heat resistant material to at least 8", install hood and observe profiles shown in |
|
|
| Figure 8, page 14; OR extend heat resistant material to at least 12" and observe profiles |
|
|
| shown in Figure 7, page 14. |
|
|
|
|
|
TABLE B - Heat Resistant Material Heights and Mantel Location
43D0122 | 13 |