ELECTRICAL WIRING (MILLI-VOLT)

The milli-volt valve is a self-powered combination gas control THAT DOES NOT REQUIRE 110 VAC TO

OPERATE.

CAUTION

Label all wires prior

to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

Wall

Switch

On/Off

Switch

TH = 3

TP = 1

TP/TH = 2

ODS

Pilot

On/Off

Switch

ODS

Pilot

Millivolt

Valve

Spade

Terminal

Red

Red

Switch

Optional Wall

Switch or Remote

Figure 15 - Wiring Diagram

CONNECTING OPTIONAL WALL SWITCH OR THERMOSTAT

Receiver

1.Use 18 awg, two-wire cable, 20 feet maximum length (15 feet of wire is supplied in accessory kits).

2.At one end of the cable, connect both wires to the wall switch or thermostat. At the other end, connect one wire to TP/TH and one wire to TH, or connect the wall switch/thermostat to the two male (0.25") terminals on the right side of the unit. The color of the wires does not matter.

20

43D0122

Page 20
Image 20
Monessen Hearth dst30 Electrical Wiring MILLI-VOLT, Operate, Connecting Optional Wall Switch or Thermostat