CLEARANCES AND HEIGHT REQUIRMENTS

Heat

Resistant

Material

10" or less

12" min. 28"

Heater in

Fireplace or Example: The bottom of the mantel may project from the wall a

Firebox

maximum of 10" at a minimum of 28" above the firebox.

 

Mantel

Minimum of 8"

Heat

Resistant

Material

Figure 7 - Minimum Mantel Clearance with No Hood

7"

 

 

 

6"

 

 

Figure 8 is an example of an unsafe mantel installation.

 

 

 

 

 

 

This mantel projects 4" at 13" above the opening, exceeding

 

 

 

the maximum acceptable distance of 21/2" The mantel also

 

 

 

projects 7" at 17" above the opening, exceeding the maximum

 

 

 

acceptable distance of 6".

21/2"

 

17"

If your mantel profile is unsafe, you may either:

 

 

 

 

• Raise the mantel to an acceptable height

4"

 

 

13"

 

 

 

 

OR

 

 

 

Hood

 

 

• Remove the mantel

Figure 8 - Minimum Mantel Clearance with Hood

14

43D0122

Page 14
Image 14
Monessen Hearth dst30 Clearances and Height Requirments, Maximum of 10 at a minimum of 28 above the firebox