Monessen Hearth EYF18 INSTALLATION Damper stop installation, PLACE and SECURE APPLIANCE, Page

Models: EYF24 EYF18

1 32
Download 32 pages 30.22 Kb
Page 11
Image 11
INSTALLATION

INSTALLATION

Damper stop installation:

A damper stop must be provided with the unit. Contact your dealer to obtain one. The damper stop must be installed as shown in Figure 11 to prevent full closure of the fireplace damper blade and provide a minimum 29 square inch flue opening.

Damper

Stop

Damper

 

 

 

 

 

 

 

 

 

 

 

Figure 11 -

 

 

 

 

 

 

 

 

 

 

 

FP2538

 

 

 

 

 

 

 

 

 

Damper Stop Installation

 

 

 

The fireplace and gas logs function as a

WARNING

system. If the fireplace is spilling into the

room (check with a match or a smoke stick),

 

EYF Series Unvented Gas Log Set

 

You must secure the gas log heater to the

 

fireplace floor. If not, the entire unit may move

 

when you adjust the controls. Movement of

 

unit may cause shifting of the gas logs which

WARNING

leads to sooting and improper burning.

gas log controls. This will insure adequate

 

Special care is required if you are installing

 

the unit into a sunken fireplace. You must

 

raise the fireplace floor to allow access to

 

air flow and guard against sooting. Raise

 

the fireplace floor using noncombustible

 

materials, as described in Placement in

 

a Fireplace with Restrictive Barrier on

 

Page 10.

 

 

Hole for

Screws

Grate Bar

 

Horizontal

 

Grate Bar

 

reposition the damper clamp until a positive draft is obtained by opening the damper. If negative pressure in home prevents having a positive draft, contact your dealer for assistance.

PLACE and SECURE APPLIANCE

Hook for

Grate

Middle Grate Bar

Hook for Grate

a Fireplace with Restrictive Barrier onHI

OFF

FP2539

Assembly procedure:

Figure 12

1.Center the gas log unit in the fireplace or firebox.

2.Install Grate: Insert longest middle grate bar in one of the two square holes in control panel. Be sure grate is centered. Sit horizontal bar inside two (2) hooks on front of control panel. Make certain front feet of grate are located inside front edge of fireplace or firebox.

3.Anchor holes are located on the flange of the unit. After centering the burner correctly, mark the hole positions on the fireplace/firebox floor. Drill two (2) 5/32" diameter holes approximately 1Z\x" deep.

4.Anchor the unit to the fireplace/firebox floor using the

screws provided.

Figure 12 -

Install Grate and Secure Heater to Floor of Fireplace/Firebox

65D1009

11

Page 11
Image 11
Monessen Hearth EYF18, EYF24 INSTALLATION Damper stop installation, PLACE and SECURE APPLIANCE, Assembly procedure, Page