GETTING STARTED - FEATURES and SPECIFICATIONS | EYF Series Unvented Gas Log Set |
| WARNING | • | Gloves are recommended when |
|
| ||
|
|
| handling ceramic fiber logs to prevent |
|
|
| skin irritation from loose fibers. |
|
| • | Logs are fragile - handle with care. |
|
|
|
|
Make sure you have received all parts:
Check your packing list to verify that all listed parts have been received. You should have the following:
•Unvented gas log burner assembly
•Plastic bag containing crushed volcanic rock
•Installation/operating instructions
•Two (2) anchoring screws
•Ceramic Fiber or Refractory Cement Logs
•Grate
The millivolt controlled version of this heater is the only style designed to be operated with optional devices for ON/OFF functions. The following options may be used with the millivolt controlled heater. These options are not packaged with the log set.
•Hand held Remote with receiver
•Wall thermostat with 15' wire
•Wall switch with 15' wire
•Hand held Thermostat Remote with receiver
Carefully inspect the contents for shipping damage. If any parts are missing or damaged, immediately inform the dealer from whom you purchased the appliance. Do not attempt to install any part of the appliance unless you have all parts in good condition.
What you will need for installa- tion:
You must have the following items available before pro- ceeding with installation:
•External regulator (for propane/LPG and 1/2 lb. natural gas systems only)
•Piping which complies with local codes
•Screwdriver
•Drill with 5/32 bit
•Manual shutoff valve
•Pipe sealant approved for use with propane/LPG (Resistant to sulfur compounds)
•Pipe wrench or appropriate size crescent wrench set
•Tee joint.
•Sediment trap
65D1009
GAS pressures
Control | Fuel | Manual | Millivolt |
Regulator Pressure | Nat. | 4.0” w.c. | 3.5” w.c. |
Pilot Regulator | Nat. | n/a | 3.5” w.c. |
Max. Inlet Pressure | Nat. | 10.5” w.c. | 10.5” w.c. |
Min. Inlet Pressure | Nat. | 5.0” w.c. | 5” w.c. |
Regulator Pressure | LP | 10.0” w.c. | 10.0” w.c. |
Max. Inlet Pressure | LP | 13.0” w.c. | 13.0” w.c. |
Min. Inlet Pressure | LP | 11.0” w.c. | 11.0” w.c. |
*NOTE: An external regulator is required to reduce supply pres- sure to a maximum of 13” w.c.
Gas Specifications
|
|
| Gas Rate | |
|
|
| Max.Input | Min. Input |
Model | Fuel | Control | BTU/h | BTU/h |
EYF18NM | Nat. | Manual | 30,000 | 18,000 |
EYF18PM | LP | Manual | 30,000 | 22,500 |
EYF18NV | Nat. | Millivolt | 30,000 | 20,000 |
EYF18PV | LP | Millivolt | 30,000 | 24,500 |
EYF24NM | Nat. | Manual | 36,000 | 19,000 |
EYF24PM | LP | Manual | 36,000 | 25,000 |
EYF24NV | Nat. | Millivolt | 36,000 | 24,000 |
EYF24PV | LP | Millivolt | 36,000 | 29,000 |
ignition controls
Piezo ignitor allows ignition of the pilot without the use of matches or batteries.
Manual control has three (3) positions:
OFF - All gas to the gas logs is shut off at the valve. IGN - Valve position to light/maintain a standing pilot. HI/LOW - Variable position corresponding to desired flame height (heat input)
Millivolt control has four (4) positions:
OFF - All gas to the gas logs is shut off at the valve. IGN - Valve position to light/maintain a standing pilot. ON - Valve position to turn ON/OFF log set with remote switch/thermostat.
HI/LOW - Variable position to control flame height (heat output).
Pilot
The gas log heater is fitted with a specially designed safety pilot light (ODS assembly) which senses the amount of oxygen available in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level. The pilot can only be relit when adequate fresh air is available.
Thermal Generator
The millivolt gas log pilot is fitted with a millivolt generator to provide power for remote activation.