LOG PLACEMENT | EYF Series Unvented Gas Log Set |
| The positioning of the logs is critical to the safe and clean operation of | |
WARNING | this heater. Sooting and other problems may result if the logs are not | |
properly and firmly positioned in the appliance. Never add additional | ||
| ||
| logs or embellishments such as pine cones, vermiculite or rock wool | |
| to the heater. Only use the logs supplied with the unit. | |
| Failure to position the parts in accordance with diagrams below or to use | |
| only parts specifically approved for this heater may result in property | |
| damage or personal injury. | |
|
|
Before you begin — This unit is supplied with a four ceramic fiber log units. Do not handle the log unit with your bare hands. Always wear gloves to prevent skin irritation from ceramic fibers. After handling the log unit, wash your hands gently with soap and water to remove any traces of fibers.
Install EYF24-F log unit on burner
Figure 18
1.Install Main Log (#1) on middle and rear supports of base. Tabs should fit inside log center opening. Check log position and stability.
2.Install Front Log (#2) in front of burner and behind grate.
3.Rest rear end Top Left Log (#3) in the indention on the main log. Line up hole in bottom of Top Left Log (#3) with slot on Front Log.
4.Position rear end of Top Right Log (#4) on indention of main log. Rest front end of Top Right Log (#4) on front lot.
Top Left Log #3
Main Log #1
Front Log #2
Top Right Log #4
Place the decorative rock
| DO NOT sprinkle volcanic rock on the logs | |
| or around the pilot or the main burner. This | |
WARNING | may cause sooting. Only place volcanic rock | |
on the floor of the fireplace. | ||
| ||
| During initial operation of the new heater, | |
| burning logs will give off a paper burning | |
| smell and orange flames will be present. | |
| Simply open the windows for a few hours | |
| to vent the odor. | |
|
|
Grate Bars
Figure 18 -
Tabs
LG706
65D1009 | 15 |