Monessen Hearth EYF24, EYF18 manual EYF Series Unvented Gas Log Set, Important Safety Information

Models: EYF24 EYF18

1 32
Download 32 pages 30.22 Kb
Page 4
Image 4
IMPORTANT SAFETY INFORMATION

EYF Series Unvented Gas Log Set

IMPORTANT SAFETY INFORMATION

16.Keep room area clear and free from combustible materials, gasoline and other flammable vapors and liquids.

17.Unvented gas heaters are a supplemental zone heater. They are not intended to be a primary heating appli- ance. Water vapor produced by an unvented heater can create moisture problems in a home when oper- ated for extended periods of time.

18.During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, films or bonding agents. These chemicals are not harmful but may produce annoying smoke and smells as they are burned off during the initial operation of the appliance; possibly causing headaches or eye or lung irritation. This is a normal and temporary occurrence.

The initial break-in operation should last two to three hours with the burner at the highest setting. Provide maximum ventilation by opening windows or doors to allow odors to dissipate. Any odors remaining after this initial break-in period will be slight and will disappear with continued use.

19.Input ratings are shown in BTU per hour and are for elevations up to 2,000 feet. For elevations above 2,000 feet, input ratings should be reduced 4 percent for each 1,000 feet above sea level. See the National Fuel Gas Code.

20.The heater and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).

21.The heater must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

22.Do not use this room heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

23.This appliance must not be used with glass doors in the closed position. This can lead to pilot outages and severe sooting outside the fireplace.

24.Never burn solid fuels in a fireplace where a unvented room heater is installed.

25.Always have a fireplace screen in place when the ap- pliance is in operation and , unless other provisions for combustion air are provided, the screen shall have an opening(s) for induction of combustion air.

This appliance may be installed in an after- market, permanently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This ap- pliance is not convertible for use with other gases.

Attention Massachusetts Residents:

This product must be installed by a licensed gas fitter.

CODES

WARNING

Never connect unit to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

Adhere to all local codes or, in their absence, the latest edition of THE NATIONAL FUEL GAS CODE ANSI Z223.1 or NFPA54 which can be obtained from…

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

or

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

65D1009

Page 4