ELECTRICAL WIRING - MILLIVOLT

EYF Series Unvented Gas Log Set

ELECTRICAL WIRING - MILLIVOLT

Connecting optional Remote Re- ceiver

Follow instructions supplied with the remote

1.Connect the wires to the two .25" male connectors located on the left side of the valve when facing the unit. Page 19, Figure 16. Do not let wire touch grate or burner.

2.Stick velcro pads with self-adhesive backing to the right side of remote receiver and to the left side of the unit. Figure 17

3.Attach remote receiver with velcro pads. Control switch must face forward.

NOTE: Heat reduces battery life. You can protect the receiver and extend battery life by mounting the receiver in a wall or other location outside the fireplace.

CHECKING SYSTEM OPERATION

The millivolt system and individual components may be checked with a millivolt meter having a 1-1000 mV range. Conduct each check shown in chart by connecting meter test leads to terminals as indicated.

A.Complete Millivolt System Check

(“A” Reading - Thermostat contacts CLOSED - Control knob “ON” - Main burner should turn ON)

1.If reading is more than 175 millivolts and the au- tomatic valve still does not come on, replace the control.

2.If the closed circuit reading (“A” reading) is less than 175 millivolts, determine cause for low read- ing, proceed to Section B.

B.Thermopile Output Reading Check

(“B” Reading - thermostat contacts OPEN - Main burn- er OFF

1.Check gas pressure to the unit. If gas pressure is within minimum and maximum on data plate, then check pilot voltage, 500 millivolts minimum. If the minimum millivolt reading is not obtainable, replace pilot.

 

 

 

Connect

Switch or

Meter

Check

 

 

Meter Leads

Thermostat

Reading

Test

To Test

 

To Terminals

Contacts

Should Be

A

Complete

 

2 & 3

Closed

Minimum 175

 

System

 

 

 

 

B

Thermopile

 

1 & 2

Open

Minimum 500

 

Output

 

 

 

 

 

 

 

Velcro

 

 

 

Remote

 

Pads

 

 

 

 

 

 

 

 

Receiver

 

 

 

 

 

SKYTECH

 

 

 

 

 

OFF

REMOTE

 

 

 

 

 

ON

 

 

Figure 17 -

Install Remote Receiver

Connecting optional Remote Re- ceiverHIFollow instructions supplied with the remote OFF

FP2540

14

65D1009

Page 14
Image 14