Monessen Hearth MJ27NR, MJ27PR operating instructions CLEARANCES and HEIGHT requirements, 12 min

Models: MJ27NR MJ27PR

1 40
Download 40 pages 38.77 Kb
Page 14
Image 14
CLEARANCES and HEIGHT requirements

CLEARANCES and HEIGHT requirements

 

12"

 

10"

 

8"

Heat

6"

21/2"

Resistant

Material

 

 

8" 141/2"185/8" 221/2" 26"

 

Hood

 

Heater in

 

Fireplace or

 

Firebox

 

FP1999

Example: A mantel may project from the wall a maxi- mum of 21/2" at a minimum of 8" above the opening, and a maximum of 6" at a minimum of 141/2" above the opening.

Figure 7 - Minimum Mantel Clearance with Hood - All Models

10" or Less

Heat Resis- tant Material

12" min. 28"

Heater in Fire-

place or Firebox

FP2001

Example: The bottom of the mantel may project from the wall a maximum of 10" at a minimum of 28" above the opening.

Figure 8 - Minimum Mantel Clearance with No Hood — MJ27