FLOOR CLEARANCE

FLOOR CLEARANCE

The gas log heater must be installed at least 13/8" above any combustible flooring material, such as carpeting or tile, which is closer than 14" to the base of the fireplace. The minimum distance must be maintained from the top surface of carpeting, tile, etc. Figure 10

OR

The gas log heater may be installed nearer to the floor if a minimum of 14" of noncombustible material such as slate or marble is installed between the base of the fireplace and the combustible flooring. Figure 11

Heater in

Fireplace or

Firebox

Combustible

Material

13/8" Minimum

FP2003

Figure 10 - Minimum Clearance above Combustible Flooring

Heater in

Fireplace or

Firebox

Combustible

Material

Manual background 14" Minimum

 

 

 

FP2004

This Distance May Now be

 

 

Less Than 13/8"

Figure 11 - Minimum Clearance above Combustible Flooring with

Noncombustible Material Installed at Base of Fireplace