3460 Fast’R

B-8

S7 Parameter

The S7 parameter is country-specific for France only.

France

Command Command Name Default

Option Available

Options
ATS0 Ring Count to Answer On 3 0, 3, 4
AT*DR or AT*RD Auto Redial 0 0 - 5
ATS6 Blind Dial 3 3
AT*TT Call Time-Out 5 0, 1, 2, 3, 5
ATS10 DCD Loss Disconnect 30 0, 30
AT*PT Dial Type 1 0, 1, 2
AT*DX Dial Transmit (Tx) Level 10 0 - 30
AT*DD Dial Wait 4 3, 4
ATS11 DTMF Tone Length 72 72
AT&G Guard Tone 2 1, 2
ATH LAL Busy Out Not
allowed
AT*LX Leased-Line Transmit (Tx) Level 9 9 - 30
ATS8 Pause Delay 3 3, 6, 9, 12
AT&P Pulse Dial Cycle 1 1
ATS30 Terminal Inactivity Timer 0 0 - 255
Other country-specific restrictions:
France restricts S7 (Wait for Carrier). If the country code is France, the modem
automatically sets S7=140. The available options are 2- 150.
The characters AT or at precede all commands except: +++, #####, and A/
S-Register Command Cross-Reference

Register Parameter Command Description

... ... ... ...
S7 Wait For Data Carrier
(Country-specific for
France only)
ATS7 =n
AT*D D9
AT*TT5
Set duration
Dial Wait=S7
Call Timeout=S7
... ... ... ...
*Changed values are not automatically stored to non-volatile memory. To retain
changed values, save them to an option set.