Motorola operation manual Forward Path, Return Path, BLE100 block diagram

Models: BLE100

1 48
Download 48 pages 20.74 Kb
Page 18
Image 18

Overview2-7

Forward Path

The operational gain of the BLE100 amplifiers is 34 dB with 16 dB of return loss. The operating gain includes provisions for the insertion loss of the input cable equalizer and required reserve gain to operate the Bode equalizer in the middle of its range. The low-noise figure, pre-amplifier stage, is a 1 GHz hybrid followed by a power-doubled output stage. Between the two stages is a JXP-*B pad socket, the Bode board, and the flatness and equalizer board. Because these losses are located interstage, the noise figure is only significantly impacted by the insertion loss of the forward cable equalizer or broadband cable simulator, and the input pad if its value is increased from zero.

Figure 2-7 illustrates the interconnection among these components:

Figure 2-7

BLE100 block diagram

Input port

 

 

-20 dB

 

 

TP

 

-1.7

 

 

RF/

 

H

dB F

 

AC RF

 

 

-1.0

 

L

AC

 

dB R

 

 

 

 

-1.0 dB

SFE or

SCS

-1.0 dB -1.0 dB

 

28 dB

 

~ -3 dB

 

-1.0 dB

-6.5 dB

23 dB

 

 

 

OnBrd

 

 

 

 

 

 

JXP-B

PP

JXP-B

RC

 

LDR

 

BODE

PD

Atten

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-1.7

 

Output

 

 

 

-1.0 dB

H

 

RF/

port

Manual

Auto

 

dB F

 

 

 

 

RF

AC

 

 

 

 

-1.0 dB

 

-1.0

 

 

 

 

L

AC

 

 

 

 

 

dB R

 

 

 

 

 

 

 

 

 

 

ADU/

JXP-B

OnBrd

 

 

 

 

 

 

TDU

Atten

 

 

 

 

 

 

 

 

 

 

 

 

-0.4 dB

TP

-20 dB

Surge

protector

-0.5 dB

SRE

Power

Block

Jumper

Therm

AC test

point

 

 

 

 

 

 

 

Status

 

 

 

 

 

 

 

TP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Return

 

 

 

 

 

 

 

monitor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JXP-B

 

injection point

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-20 dB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-0.4 dB

 

 

 

 

+30.0 dB -0.3 dB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-0.4 dB

 

 

 

 

Surge

 

 

JXP-B-

 

LPF

 

 

 

ICS

 

JXP

 

 

 

 

 

 

 

 

 

protector

TP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-20 dB

 

 

 

 

 

 

 

-16 dB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

 

 

 

 

 

 

 

 

24 Vdc

 

 

 

 

 

 

supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC test point

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fuse

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

** Plug-in module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FTEC

Return Path

The circuit board of the BLE100 includes the return path. This equips the BLE100 to pass signals in the return or upstream direction. The standard circuit board contains all components including the diplex filters with extended return bandwidth for the amplifier input and output.

Optional SRE-*-* return equalizers compensate for cable attenuation and are available in 1 dB increments for S-split, and 2 dB increments for all other splits, from 0 dB through 12 dB.

BLE100 Installation and Operation Manual

Page 18