Motorola CME-12D60 Mon-Sel Jumper, Pgpull / Phpull Jumpers, JP1 Oscillator Select JUMPER

Models: CME-12D60

1 19
Download 19 pages 25.75 Kb
Page 11
Image 11

JUMPERS

MON-SEL JUMPER

Selects which firmware monitor in External EPROM (U6/7) the board will execute upon reset in expanded mode with monitor enabled by CONFIG SWITCH position 4.

ON

Mon12 Debug Monitor

OFF

Third party firmware support (NoICE, Metrowerks, etc.)

PG_PULL / PH_PULL JUMPERS

Pull up or Pull down I/O line bias resistor option jumpers. When port G or Port H are configured as inputs these options select which way the internal pull resistor’s operate.

Port H should be in the pull down state if KEYPAD is used.

GND

Pull Down active (default)

+5V

Pull Up active

JP1 Oscillator Select JUMPER

Provides enabling and Disabling of the internal PLL and external clock oscillator X1.

Default configuration is XCLK position. The PLL is disabled in this position and the oscillator is provided by X1 external clock.

PLL

Enables PLL crystal oscillator (see below)

XCLK

Disables PLL crystal oscillator (R1 should be installed) default

To enable PLL clock do the following:

1.Remove R1 on the bottom of the board to isolate the X1 external clock input to the PLL oscillator.

2.Install user selected Y1, C1 and C2 to provide new oscillator clock.

3.Install RX1, CX1 and CX2 to provide correct XFC conditioning for the frequency of operation desired. NOTE: see MC68HC912D60 user manual for more information.

4.Move JP1 to the PLL position.

5.Note that the provided firmware utilities (Mon12, NoICE, etc) in External EPROM will not operate with PLL enabled.

11

Page 11
Image 11
Motorola CME-12D60 manual Mon-Sel Jumper, Pgpull / Phpull Jumpers, JP1 Oscillator Select JUMPER, Mon12 Debug Monitor