Diagnostics 4-15
The Code Modules fields are: Field Description
Boot Code The boot code version in ASCII format
Version The firmware version and build date in ASCII format
Digital Secure Processor The digital secure processor version in ASCII format
Downloadable Object
Information Table
Lists all objects loaded, or being loaded, onto the DCT3412 in ASCII format. The
information displayed for each object depends on the running environment. If a
download is not in progress, the LED displays the current environment running and
version number, as shown in Figure 4-9. On the LED, “bPC” represents base
platform or Thin Client code.
Object The object name
Ver The object version
Status The object status, updated on the OSD and LED every 5 seconds while you display
the diagnostic:
OSD Status Description
MEM ALLOC Allocated Memory for object is allocated
LOADING Loading Object is being loaded
STARTING Enabling Object is being started (the constructor is
running)
ENABLED Enabled Object is running
ENA–NOT RUN Enabled_Not_
Runnable
Object is enabled, but cannot run
STOPPING Disabling Object is being stopped (the destructor is
running)
DISABLED Disabled Object has been disabled
DIS-NOT RUN Disabled_Not_
Runnable
Object is disabled and cannot run
DELETING Deleting Object is being deleted
POSTPONED Postponed Object cannot run on the current system;
it will be enabled during the next boot
CONNECTED Connect Connected to download PID awaiting
data
PEND CONNECT TryingToConnect Trying to connect
ID The object identifier
DCT3412 Installation Manual