DiagnosticsB-15
d 09: Upstream Modem (STARVUE II Diagnostics)
This diagnostic shows the status and operating parameters for the STARVUE II RF return:
STARVUE II DIAGNOSTICS |
| |
STATUS: |
| DISABLED |
FREQUENCY: |
| 23.000 MHz |
LEVEL: |
| 39 |
IPPV: |
| DISABLED |
170 | 20:49:33 | |
|
|
|
The STARVUE II Diagnostics fields are:
Field | Description |
|
Status | Indicates the transmitter status: | |
| - | Idle |
| t | Transmitting |
Frequency | Indicates the transmitting frequency. | |
Level | Indicates the approximate power value of the STARVUE II transmitter in dBmV. The | |
| difference between the power value on the diagnostic screen and the actual power of the | |
| STARVUE II module may be ± 5 dBmV. | |
IPPV | Indicates the Interactive | |
| ENABLED | IPPV enabled |
| UNSENT − ## | The |
|
| number of unsent transactions. |
| DISABLED | IPPV disabled |
Last Line | Displays the sequence number, time, and date of the last poll message. |
d 10: Application (APP) Code Modules
This diagnostic displays the currently downloaded code modules. This can be a
APP CODE MODULES
ASTB xxxx | aaa | bbb | ccc |
|
MODULE |
| VER | STATUS | ID |
| 07.72 | ENABLED | 0001 | |
Appl_____ |
| 02.00 | DOWNLD | 07DA |
|
|
|
|
|