Error Codes

DiagnosticsB-5

Error Codes

A sequence of LED flashes communicates errors when errors occur. The errors associated flash sequences, causes, and remedies are:

Code

Flash Sequence

Cause

Remedy

E 00

None; no error condition exists

Indicates normal condition after

Not applicable

 

 

initialization

 

E 01

MESSAGES LED flashes on and off

The set-top did not receive a

Restore out-of-band signal

 

 

connect message

Send a connect message

E 02

Repeating series of two MESSAGES

Init Error

The set-top needs a power

 

LED flashes, separated by a

 

cycle to recover

 

pause

 

 

E 03

Repeating series of three

DRAM error

Not used at this time

 

MESSAGES LED flashes, separated

 

 

 

by a pause

 

 

E 04 Repeating series of four MESSAGES LED flashes, separated by a pause

E 07 Repeating series of seven MESSAGES LED flashes, separated by a pause

E 08 Repeating series of eight MESSAGES LED flashes, separated by a pause

E 09 Repeating series of nine MESSAGES LED flashes, separated by a pause

E 10 POWER LED flashes on and off; MESSAGES LED remains off

DP-SRAM error

ROM verification failure

Faulty RAM, ROM, EEPROM, or POST failure (this is a hardware failure)

Dead battery or the memory has not been initialized; occurs if the battery fails to keep the RAM alive during power-down; causes set-top to be disconnected

Invalid serial number

Not used at this time

Power cycle the set-top; if repetitive, return for repair

Return the set-top for repair

Return the set-top for repair; requires factory initialization message

Not used at this time

E 11

POWER LED flashes once;

Invalid unit address

Return the set-top for

 

MESSAGES LED flashes once

 

repair; requires a unit

 

 

 

creation message

E 12

POWER LED flashes once;

POST failed

Not used at this time

 

MESSAGES LED flashes twice

 

 

E 13

POWER LED flashes once;

Sys_boot initialization failure

Power cycle the set-top; if

 

MESSAGES LED flashes three times

 

repetitive, return for repair

E 14

POWER LED flashes once;

System startup failure

Power cycle the set-top; if

 

MESSAGES LED flashes four times

 

repetitive, return for repair

E 15

POWER LED flashes once;

TSI structure is corrupted

Power cycle the set-top; if

 

MESSAGES LED flashes five times

 

repetitive, return for repair

E 16

POWER LED flashes once;

Bad flash number specified for

Error logged, ignore

 

MESSAGES LED flashes six times

Initiate Flash Platform

 

E 17

POWER LED flashes once;

Bad platform validation

Error logged, ignore

 

MESSAGES LED flashes seven

step number

 

 

times

 

 

Only the ALPS TDER1-0001 A appears on the on-screen display.