What You Will Need
ML910 R1.0 RF Pass-through Upgrade Procedure, Version A
Purpose and Requirements
2 Support RF Pass-through in Retrofitted ML900 Docking Stations
ML910 R1.0 RF Pass-through Upgrade Procedure, Version A
Step-by-Step Procedure
ML910 R1.0 RF Pass-through Upgrade Procedure, Version A
To determine the EC BIOS version
I. EC BIOS Upgrade Procedure
Perform Procedures I, II and III in order
ML910 R1.0 RF Pass-through Upgrade Procedure, Version A
ML910 R1.0 RF Pass-through Upgrade Procedure, Version A
5. Click on “Image, Project, Copy”
6. Click on “Disc Image or Saved Project”
ML910 R1.0 RF Pass-through Upgrade Procedure, Version A
9. Burning process and status are displayed
ML910 R1.0 RF Pass-through Upgrade Procedure, Version A
a. Click Start Control Panel Add or Remove Programs
II. ML User Application Upgrade Procedure
a. MLSERVICE folder
ML910 R1.0 RF Pass-through Upgrade Procedure, Version A
6. Double-click on SETUP.EXE in the MLSERVICE folder
ML910 R1.0 RF Pass-through Upgrade Procedure, Version A
5. Click Yes to install Microsoft Visual C++ 2005 Runtime Libraries
7. Click the Next button to continue
9. Click the Next button to start the installation
ML910 R1.0 RF Pass-through Upgrade Procedure, Version A
8. Accept the default settings and click the Next button
10. Please wait while MLService is being installed
ML910 R1.0 RF Pass-through Upgrade Procedure, Version A
14. Accept the default settings and click the Next button
ML910 R1.0 RF Pass-through Upgrade Procedure, Version A
12. Double-click on SETUP.EXE in the MLUA folder
13. Click the Next button to continue
ML910 R1.0 RF Pass-through Upgrade Procedure, Version A
15. Click the Next button to start the installation
16. Please wait while ML User Application is being installed
ML910 R1.0 RF Pass-through Upgrade Procedure, Version A
17. Click on the Close button when ML User Application is successfully installed
b. Select ML Administrator Application and click Remove to uninstall
III. ML Administrator Application Upgrade Procedure
2. Uninstall the existing version of the ML Administrator Application
ML910 R1.0 RF Pass-through Upgrade Procedure, Version A
ML910 R1.0 RF Pass-through Upgrade Procedure, Version A
4. Double-click on setup.exe 5. Click the Next button to continue
6. Accept the default settings and click the Next button
ML910 R1.0 RF Pass-through Upgrade Procedure, Version A
7. Click the Next button to start the installation
8. Please wait while ML Administrator Application is being installed
ML910 R1.0 RF Pass-through Upgrade Procedure, Version A
9. Click on the Close button when ML Administrator Application is successfully installed
IV. Enabling the RF Pass-Through Option Using MLAA and MLUA
ML910 R1.0 RF Pass-through Upgrade Procedure, Version A
ML910 R1.0 RF Pass-through Upgrade Procedure, Version A
5. Launch the ML User Application
ML910 R1.0 RF Pass-through Upgrade Procedure, Version A
11. Note that the RF Pass-Through Option will not be applicable under the following conditions