59
Mount PIDU+ at a
height that protects
it from flooding or
rising damp
To ODU
AC Mains
Power Ethernet
Drip Loop
Optional Drain Hole
Figure 23 - PTP 400 Series Bridge PIDU Plus Drip Loop Configuration
WARNING: It is possible for moisture to enter the cable due to damage to the outer protective
layer. This moisture can track down the inside of the cable, filling up the drip loop and
eventually finding its way into the PIDU Plus. To protect against this the outer protective layer
of the cable can be opened up at the bottom of the drip loop to allow this moisture to escape.
WARNING: Some network operators employ gel filled cables to get around the problem of
moisture ingress and transmission. The PTP 400 Series Bridge has NOT been tested using