8.3.5 Install Wizard Pages
These pages are used during system installation. There follows a description of the install
pages along with their use during the installation configuration process. The actual installation
process is described in section 7.7.10 “Aligning the ODUs”.
All wireless links are shipped as paired units. They are pre-configured at the factory so that
they can be installed without the user supplying any configuration. Each wireless link is
shipped with a Quick Start Guide. Attached to the Quick Start Guide is a summary of the
default configuration data. Table 11 shows a sample link configuration. The values highlighted
have been committed to the wireless units non-volatile storage.
Example PTP 400 Series Bridge Configuration Data
For your convenience these two units have been pre-configured as a link
Units:
ODU serial number ODU serial number
0167800002BE 0167800002BF
Ethernet MAC address Ethernet MAC address
00:04:56:00:02:BE 00:04:56:00:02:BF
Configured as:
Master Slave
Target MAC address Target MAC address
00:04:56:00:02:BF 00:04:56:00:02:BE
License Key License Key
A471-FE88-428D-E1F3 534F-4F54-D1B0-E2DA
IP Address IP Address
169.254.1.2 169.254.1.1
Table 11 - PTP 400 Series Bridge Factory Configuration Values
The factory default configuration is written to the ‘semi-permanent’ configuration bank.
WARNING: The factory default configuration is limited in range to 40 Km (25 miles). If you
wish to install a wireless link with a range of > 40 Km (> 25 miles) and < 200 Km (< 124 miles)
you must follow the ‘Manually Configuring the Wireless Units’ in section 8.3.5.1.