Power On Self Test (POST)

After the power has been turned on, Video Server will perform a self-diagnostic to detect any possible hardware defects. The CONNECT (LED 2) and SERIAL (LED 3) LEDs will blink during the POST, and will keep blinking until the POST completes successfully, or a fatal error is detected. If either status LED indicator is dim to start off with, the LED may be broken.

When certain fatal errors occur, LED2 and LED3 blink in a particular way to indicate the type of failure, as described in the following table.

 

LED pattern after POST

Failed function

Troubleshooting

 

LED2 and LED3 blink at same

Video input

The video decoder is broken.

 

time

 

Ask your reseller for technical

 

 

 

service.

 

LED2 ON and LED3 OFF

Ethernet network

The PCI interface cannot work.

 

 

 

Ask your reseller for technical

 

 

 

service.

 

LED2 OFF and LED3 ON

Ethernet network

The Ethernet controller is

 

 

 

broken. Ask your reseller for

 

 

 

technical service.

 

LED2 ON and LED3 ON

Ethernet interface

Ethernet interface failure

 

 

 

includes not only components on

 

 

 

board but also Ethernet cable and

 

 

 

the devices on the opposite end.

 

LED2 blink and LED3 ON

System date and time

The real-time clock is broken.

 

 

 

Ask your reseller for technical

 

 

 

service.

 

LED2 ON and LED3 blink

Camera control via COM or

The UART controller is broken.

 

 

modem interface

Ask your reseller for technical

 

 

 

service.

 

 

 

 

 

To reduce system failure caused by operation error, always read the related sections in this user’s manual to prevent unexpected errors caused by “wild-guess configuration.”

Frequently Asked Questions

Q:Why can’t I see the Video Server in the installer after rebooting?

A:The installer is only used to install the IP address of the Video Server. If the IP address is fixed by checking the option in the installer, the Video Server will no longer appear in the installer.

Q:Why can’t I connect the Video Server after rebooting?

A:If the IP address is not fixed, Video Server will always wait for the installing command to provide a valid IP address. This means that the previous IP address will not be used if the option in the installer is not checked; or the option in the network configuration is not cleared. The benefit of waiting for a valid IP address by default is that administrators can find the Video Server in the installer to prevent IP conflict. As long as the IP address is confirmed, we suggest fixing the IP address to make Video Server automatically start up whenever regaining power.

Q:What if I forget my password?

A:Every access to Video Server needs authentication. If you are not a permitted user, you may view the images or control the camera as long as the demo account is opened. The demo account user may use username as “demo” without any password to access limited features. If you are one of the managed users, you must ask the administrators for the password in the first time. If you are the administrator, there is no way to recover the root password. The only way to regain access to Video Server is to restore the factory settings and reinstall it.

7-2 VPort 2140 User’s Manual

Page 76
Image 76
Moxa Technologies 2140 user manual Power On Self Test Post, Frequently Asked Questions

2140 specifications

Moxa Technologies has established a strong reputation in the realm of industrial networking and communications, and one of their standout products is the Moxa Technologies 2140. This device serves as a versatile and robust solution for various applications in industrial settings.

The Moxa 2140 is primarily recognized for its ability to seamlessly integrate serial devices into Ethernet networks. This capability is essential in modern industrial environments, where legacy equipment must often communicate with newer systems. The device functions as a serial device server, converting serial data into Ethernet packets, enabling efficient data transmission without compromising on speed or reliability.

One of the key features of the Moxa 2140 is its support for multiple serial communication protocols, including RS-232, RS-422, and RS-485. This wide compatibility ensures that users can connect a diverse range of devices, from older machinery to contemporary sensors, without needing extensive modifications. The Moxa 2140 can handle various communication speeds, allowing for flexibility in different industrial scenarios.

In addition to its protocol support, the Moxa 2140 boasts dual Ethernet ports, which facilitate network redundancy and enhanced reliability. This capability is crucial for industrial applications that demand continuous uptime, as it minimizes the risk of network failures. The device supports both static and dynamic IP address configurations, simplifying integration into existing networks.

The Moxa 2140 is equipped with advanced security features, including secure data transmission via SSH and HTTPS. This ensures that sensitive industrial data remains protected from unauthorized access, a critical consideration in today’s cybersecurity landscape. The device also includes built-in support for SNMP (Simple Network Management Protocol), enabling administrators to monitor network status and troubleshoot issues efficiently.

Another noteworthy characteristic of the Moxa 2140 is its rugged design, built to withstand harsh industrial environments. Its robust housing protects against dust, moisture, and temperature fluctuations, making it suitable for deployment in factories, outdoor settings, and other challenging conditions.

Overall, the Moxa Technologies 2140 is a powerful and flexible tool that meets the demands of modern industrial communications. Its combination of protocol support, dual Ethernet ports, security features, and durability make it a preferred choice for companies looking to enhance their communication infrastructure while ensuring versatility and reliability in their operations.