CP-118U User’s Manual

Serial Programming Tools

ADDC™

ADDC™ is the best method for switching between transmission and receiving when using 2-wire RS-485.

When using ADDC™, additional code is not required to switch between data transmitting and receiving, since the switching mechanism is managed automatically by the board’s built-in intelligent hardware mechanism. This means that RS-485 programming using ADDC™ mode is just as simple and straightforward as RS-232 or RS-422 programming.

RTS

To ensure precise timing control when using 2-wire RS-485 transmission, we recommend that you configure your CP-118U Series ports as described below.

There are 2 methods for controlling 2-wire RS-485 transmission.

Method 1

The following method is commonly used for 2-wire RS-485 transmission:

sio_SetWriteTimeouts(port, 0);

/* Set sio_write() into block mode if for Windows NT and

 

Windows 95/98 */

sio_RTS(port, 1);

/* Turn on RTS signal. The RS-485 port is ready for

 

transmitting data. */

sio_write(port, buff, 10);

/* Write 10 byte characters in "buff". The function blocks

 

until the last character is transmitted */

sio_RTS(port, 0);

/* Turn off RTS signal. The RS-485 port is ready for

 

receiving data. */

sio_read(port, buff, 10);

/* Read 10 bytes */

Method 2

The PComm or API-232 library includes a dedicated RS-485 function that integrates the functions described in Method 1 above into one function:

sio_putb_x(port, buff, tick );

/* 1. Turn on RTS and ready for transmitting data.

 

2. Send data.

 

3. Wait for tick time.

 

4. Turn off RTS and ready for receiving data. */

To see more detailed information about these functions, refer to the PComm library’s on-line Help file for Windows 95/98/NT/2000/XP/2003.