Installation

Electrical Connections

Note:

Leave enough electrical cable behind the machine so that the dishwasher can be pulled forward a minimum of two feet to be serviced.

Warning:

Electrical and grounding connections must comply with all local electrical codes or in the absence of local codes then connections must comply with the National Electrical Code.

Warning: When working on the dishwasher, disconnect the main electric service and tag it to indicate work is being done on that circuit.

1.The electrician should compare the electrical specifications on the machine electrical data plate (located in the control panel) to the electrical power supply before connecting the machine to the incoming service at a fused disconnect switch.

IMPORTANT: The 208-240V/60Hz/1PH electrical supply service for this machine must be a 2-wire plus ground service. For optional 208-240V/60Hz/3PH the electrical supply service must be a 3-wire plus ground service.

2.On the 208V-240V models, a knockout is provided at the rear of the junction box for electrical service connections. A fused disconnect switch or circuit breaker (supplied by user) is required to protect each power supply circuit.

Refer to the MACHINE ELECTRICAL CONNECTION DATA PLATE for the dishwasher power requirements.

3

Page 11
Image 11
Moyer Diebel 301HT M2 installation manual Electrical Connections