Installation

Chemical Dispensers

ATTENTION:

Chemical dispensers must be electrically grounded in compliance with applicable electric codes.

adapter (supplied by others). Do not connect drain hose to a 90° drain fitting.

Detergent

The machine is equipped with an automatic detergent dispensing pump system.

1.Use a qualified detergent/chemical supplier for your detergent.

2.Your machine is supplied with a detergent dispensing pump that is internally wired and ready for use. Use a commercial grade liquid detergent and insert the red pickup tube into the detergent container. The pickup tube has a strainer on the end to prevent the crystallized chemical from clogging the supply lines.

Always wash hands under running water if they come into contact with the detergent and comply with the instructions pertaining to the specific type of detergent.

To prime the peristaltic pump:

1.Insert pick-up tube into the detergent container.

2.Close machine door and switch machine on.

3.Push and hold the prime switch.

Rinse Aid

1.Use a qualified/chemical supplier for your rinse aid needs.

2.Insert the transparent tube into the container containing the rinsing agent.

3.Push and hold the prime switch

Completing the Installation

1.Remove any foreign materials from inside the machine.

2.Install the scrap screens, wash and rinse arms, strainer basket and overflow tube.

3.After plumbing and electrical connections are completed, check machine for water leaks by closing the door, then depressing the ON switch. This allows the tank to begin filling and to reach temperature.

4.Open the door and check the water level. The water level should be 2 inches above the scrap screen.

5. Close the door fully.

Caution:

 

Connecting chemical dispensers at points other than those recommended by the factory may damage the dishwasher electrical system. Damage caused by the installation of chemical equipment will not be covered the WARRANTY.