MR9600 User Guide
Description: Changes the drive that the user is to work with
Security: Guest
Example:
[01]A:\# B:
[02]B:\#
boot
Parameter: None
Description: Reboots the system by performing a reset of the MR9600 controller card. A prompt asks you to confirm your choice. If you wish to reboot the system, enter y. Any other key will halt the reboot operation.
Security: Supervisor
Example:
[0] A:\ # boot
Are you sure you wish to reboot the controller card? (y/n)
bpstatus
Parameter: None
Description: Displays the rack’s back plane polling activity between the controller and each powered device. Each correctly operating device responds to three specific polls; “Busy”, “No Response”, and “No Acknowledgement”. If the device does not respond the counter/s will increment. The example below shows all devices in a fully loaded CC9600 are responding correctly.
Security: Supervisor
Example:
[1] A:\# bpstatus |
|
|
|
|
| ||
Backplane Status: |
|
| Busy:NoResp:NoAck |
| |||
0:count of 0 | *:>=ninety | ||||||
Slot A | B | C D | E | F | G H | I J K L M N | O P |
1:000 000
2:000 000 000 000 000 000 000 000
3:000 000 000 000 000 000 000 000
4:000 000 000 000 000 000 000 000
5:000 000
6:000 000 000 000 000 000 000 000
7:000 000 000 000 000 000 000 000
8:000 000 000 000 000 000 000 000
9:000 000
10:000 000 000 000 000 000 000 000
11:000 000 000 000 000 000 000 000
12:000 000 000 000 000 000 000 000
13:000 000
14:000 000 000 000 000 000 000 000
15:000 000 000 000 000 000 000 000
16:000 000 000 000 000 000 000 000
[2] A:\ #
bye
Parameter: None
Description: Logs the User off of the system
32 | CommPlete Communications Server |