Multiquip DCA-25SSIU2 50 HZ- PRE-SETUP, Circuit Breakers, Lubrication Oil, Engine Oil Dipstick

Models: DCA-25SSIU2

1 82
Download 82 pages 62.92 Kb
Page 30
Image 30
Circuit Breakers

Circuit Breakers

To protect the generator from an overload, a 3-pole, 60 amp, main circuit breaker is provided to protect the U,V, and W OutputTerminals from overload.In addition two single-pole, 20 amp GFCI circuit breakers are provided to protect the GFCI receptacles from overload.Two 50 amp, 2-pole circuit breakers have also been provided to protect the auxiliary receptacles from overload. Make sure to switch ALL circuit breakers to the OFF position prior to starting the engine.

Lubrication Oil

Fill the engine crankcase with lubricating oil through the filler hole, but DO NOT overfill. Make sure the generator is level, and verify that the oil level is maintained between the two notches (Figure 31) on the dipstick. See Table 9 for proper selection of engine oil.

Figure 31. Engine Oil Dipstick

When checking the engine oil, be sure to check if the oil is clean. If the oil is not clean, drain the oil by removing the oil drain plug, and refill with the specified amount of oil as outlined in the Isuzu Engine Owner's Manual. Oil should be warm before draining.

Other types of motor oils may be substituted if they meet the following requirements:

API Service Classification CC/SC

API Service Classification CC/SD

API Service Classification CC/SE

API Service Classification CC/SF

DCA-25SSIU2 (50 HZ)— PRE-SETUP

Fuel Check

DANGER - EXPLOSION/FIRE HAZARDS

Fuel spillage on a hot engine can cause a fire or explosion. If fuel spillage occurs, wipe up the spilled fuel completely to prevent fire hazards. NEVER smoke around or near the

generator.

Refilling the Fuel System

CAUTION - REFUELINGTHE GENERATOR

ONLY properly trained personnel who have read and understand this section should refill the fuel tank system.

Located at the bottom-front of the cabinet (Figure 32) is the internal fuel tank. Some generators may be equipped with a trailer mounted fuel tank (option). ALWAYS fill the either fuel tank with clean and fresh #2 diesel fuel. DO NOT fill the fuel tanks beyond their capacities.

Pay attention to the fuel tank capacity when replenishing fuel. The fuel tank cap must be closed tightly after filling. Handle fuel in a safety container. If the container does not have a spout, use a funnel. Wipe up any spilled fuel immediately.

Figure 32. Internal Fuel Tank System

PAGE 30 — DCA-25SSIU2 (50 HZ)— OPERATION AND PARTS MANUAL — REV. #0 (03/11/05)

Page 30
Image 30
Multiquip DCA-25SSIU2 50 HZ- PRE-SETUP, Circuit Breakers, Lubrication Oil, Engine Oil Dipstick, Fuel Check