![DCA-400SPK —TROUBLESHOOTING (MPEC)](/images/new-backgrounds/88649/88649129x1.webp)
DCA-400SPK —TROUBLESHOOTING (MPEC)
TABLE 18. MPEC TROUBLESHOOTING
Sympton | Possible Cause | Solution | |
|
|
| |
| Low oil level? | Fill oil level. | |
|
|
| |
Low oil pressure | Oil pressure sending unit failure? | Replace oil pressure sending unit. | |
|
| ||
light is on. | Time delay malfuntion in MPEC? | Refer to dealer. | |
| |||
|
|
| |
| Wire shorted? | Inspect/repair wire. | |
|
|
| |
| Low coolant level? | Fill coolant level. | |
Low coolant level |
|
| |
Sending unit failure? | Replace sending unit. | ||
light is on. | |||
|
| ||
| Low battery voltage? | Replace/charge battery. | |
|
|
| |
| Fan belt tension incorrect? | Tighten/replace fan belt. | |
|
|
| |
| Air flow is not circulation through | Clean/repair radiator grill. | |
| radiator? | ||
|
| ||
|
|
| |
| Doors open? | Close doors. | |
High coolant |
|
| |
Exhaust leaking? | Replace/repair gaskets or faulty part. | ||
temperture light is | |||
|
| ||
on. | Generator being overloaded? | Check/reduce load. | |
| |||
|
|
| |
| Thermostat failure? | Replace thermostat. | |
|
|
| |
| Air intake blocked? | Clear all air intakes. | |
|
|
| |
| Temperature switch failure? | Replace temperature switch. | |
|
|
| |
Overcrank light is | No or low Fuel? | Fill fuel level. | |
|
| ||
on. | MPEC needs to be calibrated? | Refer to dealer. | |
| |||
|
|
| |
| RPM engine speed too high? | Adjust RPM. | |
|
|
| |
Overspeed light is | Governor actuator needs to be adjusted? | Adjust governor actuator. | |
|
| ||
Governor controller needs to be |
| ||
on. | Adjust governor controller. | ||
| adjusted? | ||
|
| ||
|
|
| |
| MPEC needs to be calibrated? | Refer to dealer. | |
|
|
| |
Loss of MPU | Magnetic pick up out of adjustment? | Adjust magnetic pick up. | |
|
| ||
light(s) or on. | Magnetic pick up dirty? | Clean magnetic pick up. | |
| |||
|
|
|