Battery

CAUTION:

Never over fill the battery with water above the upper limit.

The battery contains acids that can cause injury to the eyes and skin. To avoid eye irritation, always wear safety glasses. Use well insulated gloves when picking up the battery. Use the following guidelines when handling the battery:

1.DO NOT drop the battery. There is the possibility of risk that the battery may explode.

2.DO NOT expose the battery to open flames, sparks, cigarettes etc. The battery contains combustible gases and liquids. If these gases and liquids come in contact with a flame or spark, an explosion could occur.

3.Always keep the battery charged. If the battery is not charged a buildup of combustible gas will occur.

4.Always keep battery charging and booster cables in good working condition. Repair or replace all worn cables.

5.Always recharge the battery in an open air environment, to avoid risk of a dangerous concentration of combustible gases.

6.In case the battery liquid (dilute sulfuric acid) comes in contact with clothing or skin, rinse skin or clothing immediately with plenty of water.

7.In case the battery liquid (dilute sulfuric acid) comes in contact with your eyes, rinse eyes immediately with plenty of water, then contact the nearest doctor or hospital, and seek medical attention.

RULES FOR SAFE OPERATION

NEVER Run engine without air filter. Severe engine damage may occur.

Always service air cleaner frequently to prevent carburetor malfunction.

Always disconnect the battery before performing service on the generator.

Always be sure the operator is familiar with proper safety precautions and operations techniques before using generator.

Always store equipment properly when not in use. Equipment should be stored in a clean, dry location out of the reach of children.

DO NOT leave the generator running in the manual mode unattended.

DO NOT allow unauthorized people to operate this equipment.

Always read, understand, and follow procedures in Operator’s Manual before attempting to operate equipment.

Refer to the Komatsu Engine Owner's Manual for engine technical questions or information.

Loading and Unloading (Crane)

Before lifting, make sure the generator's lifting hook is secure and that there is no apparent damage to the generator itself (loose screws, nuts and bolts). If any part is loose or damaged, please take corrective action before lifting.

Always drain fuel prior to lifting.

Always make sure crane or lifting device has been properly secured to the hook of guard frame on generator.

NEVER lift the machine while the engine is running.

Use adequate lifting cable (wire or rope) of sufficient strength.

When lifting the generator, always use the balanced center-point suspension hook and lift straight upwards.

NEVER allow any person or animal to stand underneath the machine while lifting.

When loading the generator on a truck, be sure to use the front and back frame bars as a means to secure the generator during transport.

PAGE 8 — DCA-400SPK — PARTS AND OPERATION MANUAL— REV. #0 (06/19/01)

Page 8
Image 8
Multiquip DCA-400SPK operation manual Battery, Loading and Unloading Crane

DCA-400SPK specifications

The Multiquip DCA-400SPK is a powerful and versatile diesel generator designed to meet the demands of both commercial and industrial applications. Known for its robust performance and reliable operation, this generator is engineered to provide consistent power in various environments, making it a go-to solution for contractors, events, and emergency backup needs.

One of the DCA-400SPK's standout features is its Cummins QSB6.7 engine, which provides 400 kVA (kilovolt-amps) of output. This engine is renowned for its fuel efficiency and durability, ensuring that users get the most out of their investment without frequent refueling. The generator is also equipped with a two-pole alternator that contributes to its ability to handle heavy loads without compromising performance.

Another notable characteristic of the DCA-400SPK is its advanced control panel. The generator comes with a fully digital control system that offers real-time monitoring and control of the generator’s functions. This includes features such as automatic voltage regulation (AVR), which ensures stable output voltage, and can be vital for protecting sensitive electronic equipment from power fluctuations.

In terms of sound attenuation, the DCA-400SPK is designed with a sound-attenuated canopy that significantly reduces noise levels during operation. This makes it suitable for use in residential areas or other noise-sensitive locations, allowing for operation without disturbing the surrounding community.

For ease of transport, the generator includes a sturdy frame and is equipped with forklift pockets and lifting hooks. This enhances its portability, making it easier to move from one job site to another. Additionally, the unit offers comprehensive connectivity options, allowing it to interface with remote monitoring systems, which can be essential for maintenance and operational oversight.

The Multiquip DCA-400SPK also features an environmentally friendly design, with a low oil shutdown feature and a robust fuel containment system to prevent spills. This not only ensures compliance with environmental regulations but also enhances the safety of operation.

Overall, the DCA-400SPK stands out as a reliable, efficient, and user-friendly generator that meets the stringent demands of the modern world, making it a preferred choice among professionals in various industries.