DCA10SPX4/DCA10SPXU4 — SETUP

Coolant (Antifreeze/Summer Coolant/Water)

KUBOTA recommends antifreeze/summer coolant for use in their engines, which can be purchased in concentrate (and mixed with 50% demineralized water) or pre-diluted. See the KUBOTA Engine Owner's Manual for further details.

Cleaning the Radiator

The engine may overheat if the radiator fins become overloaded with dust or debris. Periodically clean the radiator fins with compressed air. Cleaning inside the machine is dangerous, so clean only with the engine turned off and the negative battery terminal disconnected.

WARNING - BURN HAZARDS

If adding coolant/antifreeze mix to the radiator, DO NOT remove the radiator cap until the unit has completely cooled. The possibility of hot! coolant exists which can cause severe burns.

Day-to-day addition of coolant is done from the recovery tank. When adding coolant to the radiator, DO NOT remove the radiator cap until the unit has completely cooled. See Table 9 for engine, radiator, and recovery tank coolant capacities. Make sure the coolant level in the recovery tank is always between the "H" and the "L" markings.

Table 9. Coolant Capacity

Engine and Radiator

1.85 Gal. (7.0 liters)

 

 

Reserve Tank

.264 Gal (1.0 liters)

 

 

Operation Freezing Weather

When operating in freezing weather, be certain the proper amount of antifreeze (Table 10) has been added.

Table 10. Anti-Freeze

Operating Temperatures

Vol %

Freezing Point

 

 

Anti-Freeze

 

 

°C

°F

 

 

 

 

50

-37

-34

 

 

 

Air Cleaner

Periodic cleaning/replacement is necessary. Inspect it in accordance with the KUBOTA Engine Owner's Manual.

Fan Belt Tension

A slack fan belt may contribute to overheating, or to insufficient charging of the battery. Inspect the fan belt for damage and wear and adjust it in accordance with the

KUBOTA Engine Owner's Manual.

The fan belt tension is proper if the fan belt bends 10 to 15

mm(Figure 18) when depressed with the thumb as shown below.

Figure 18. Fan Belt Tension

CAUTION - ROTATING PARTS

NEVER place hands near the belts or fan while the generator set is running.

NOTE

When the antifreeze is mixed with

water, the antifreeze mixing ratio

 

 

must be less than 50%.

DCA10SPX4/DCA10SPXU4 — OPERATION AND PARTS MANUAL — REV. #0 (08/05/09) — PAGE 27

Page 27
Image 27
Multiquip DCA10SPXU4 Operation Freezing Weather, Vol % Freezing Point, Air Cleaner Fan Belt Tension, Must be less than 50%

DCA10SPXU4, DCA10SPX4 specifications

The Multiquip DCA10SPX4 and DCA10SPXU4 are highly regarded portable diesel generators that cater to a wide range of applications, from construction sites to outdoor events. These models are part of Multiquip’s popular line of reliable power solutions, designed to deliver robust performance and versatility.

At the heart of both models lies a powerful and efficient Yanmar diesel engine. The DCA10SPX4 offers a rated output of 10 kVA, while the DCA10SPXU4 provides the same output, making both models suitable for powering tools, lights, and other equipment. The Yanmar engine is known for its efficiency, offering longer run times between refueling and lower operational costs, making these generators economical choices for users.

One of the standout features of the DCA10SPX4 and DCA10SPXU4 is their durability and rugged design. Constructed with a powder-coated steel frame, these generators can withstand harsh environments and heavy use. The enclosed design reduces noise levels, making them ideal for urban jobsites or residential areas where noise restrictions may apply. Additionally, the weather-resistant design enhances their usability in unfavorable weather conditions.

Both models come equipped with advanced monitoring features and controls that make operation straightforward. An easy-to-read digital display provides real-time information regarding output voltage, frequency, and engine performance. This allows operators to monitor their generator’s performance swiftly and efficiently, ensuring smooth operation throughout usage.

In terms of safety, the DCA10SPX4 and DCA10SPXU4 incorporate various protective mechanisms. They include an automatic shutdown feature that activates in the event of low oil pressure or overheating, protecting the engine from damage. Furthermore, the generators are equipped with overload protection to prevent equipment damage from excessive loads.

Another notable characteristic is the generator's portability. Both models feature a compact design, lightweight structure, and integrated lifting hooks, making them easy to transport and position on job sites. Their user-friendly design allows for quick setup and disassembly, ensuring minimal downtime for users.

Overall, the Multiquip DCA10SPX4 and DCA10SPXU4 generators combine efficiency, durability, and user convenience, making them an outstanding choice for professionals seeking dependable power solutions in various applications. Whether powering construction tools or supporting outdoor events, these generators deliver reliable performance tailored to meet diverse energy needs.