MAINTENANCE

 

Table 12. Inspection/Maintenance

10 Hrs

250 Hrs

500 Hrs

 

1000

 

DAILY

 

Hrs

 

 

 

 

 

 

Check Engine Fluid Levels

X

 

 

 

 

 

Check Air Cleaner

X

 

 

 

 

 

Check Battery Acid Level

X

 

 

 

 

 

Check Fan Belt Condition

X

 

 

 

 

 

Check for Leaks

X

 

 

 

 

 

Check for Loosening of Parts

X

 

 

 

 

 

Replace Engine Oil and Filter * 1

 

X

 

 

 

Engine

Clean Air Filter

 

X

 

 

 

 

Check Fuel Filter/Water Separator Bowl

X

 

 

 

 

 

Clean Unit, Inside and Outside

 

X

 

 

 

 

Change Fuel Filter

 

 

X

 

 

 

Clean Radiator and Check Coolant Protection Level*2

 

 

X

 

 

 

Replace Air Filter Element * 3

 

 

X

 

 

 

Check all Hoses and Clamps * 4

 

 

 

 

X

 

Clean Inside of Fuel Tank

 

 

 

 

X

Generator

Measure Insulation Resistance Over 3M ohms

 

X

 

 

 

Check Rotor Rear Support Bearing

 

 

X

 

 

 

 

 

 

 

*1

Replace engine oil and fi lter at 100 hours, fi rst time only.

 

 

 

 

 

*2

Add “Supplemental Coolant Additives (SCA’S)” to recharge the engine coolant.

 

 

 

*3

Replace primary air fi lter element when restriction indicator shows a vacuum of 625 mm (25 in. H20).

 

*4

If blowby hose needs to be replaced, ensure that the slope of the blowby hose is at least a 1/2 inch per foot,

 

with no sags or dips that could collect moisture and/or oil.

 

 

 

 

 

GENERAL INSPECTION

Prior to each use, the generator should be cleaned and inspected for defi ciencies. Check for loose, missing or damaged nuts, bolts or other fasteners. Also check for fuel, oil, and coolant leaks. Use Table 12 as a general maintenance guideline Engine Side (Refer to the Engine Instruction Manual)

AIR CLEANER

Every 250 hours: Remove air cleaner element (Figure 58) and clean the heavy duty paper element with light spray of compressed air. Replace the air cleaner as needed.

Air Cleaner with Dust Indicator

This indicator (Figure 56) is attached to the air cleaner. When the air cleaner element is clogged, air intake restriction becomes greater and the dust indicator signal shows RED meaning the element needs changing or service. After changing the air element, press the dust indicator button to reset the indicator.

Figure 58. Air Cleaner/Indicator

NOTICE

The air fi lter should not be changed until the indicator reads “RED”. Dispose of old air fi lter. It may not be cleaned or reused.

PAGE 38 — DCA250SSI/DCA250SSIU GENERATOR • OPERATION AND PARTS MANUAL — REV. #0 (01/12/11)

Page 38
Image 38
Multiquip DCA250SSIU manual Maintenance, General Inspection AIR Cleaner, Air Cleaner with Dust Indicator

DCA250SSIU, DCA250SSI specifications

The Multiquip DCA250SSI and DCA250SSIU are powerful diesel generators designed to meet the demanding energy needs of various industries. These models are specifically engineered for reliability, efficiency, and performance, making them suitable for commercial applications, construction sites, and emergency backup power.

One of the standout features of both the DCA250SSI and DCA250SSIU is their impressive power output. Each model is capable of delivering 250 kVA, allowing users to run multiple equipment and tools simultaneously without worrying about power shortages. This makes them ideal for large-scale operations where consistent power is critical.

Both generators are equipped with a robust industrial-grade engine, ensuring long-lasting performance and durability. The DCA250SSI features a Kohler 4038T, whereas the DCA250SSIU includes a Yanmar engine. These engines are designed to operate efficiently under heavy loads while minimizing fuel consumption. The advanced design helps reduce emissions, making these models environmentally friendly.

The DCA250SSI and DCA250SSIU come with a sound-attenuated enclosure, which significantly reduces noise levels during operation. This design makes them suitable for use in urban settings or noise-sensitive environments, allowing businesses to comply with regulations without compromising on power supply.

Furthermore, both models integrate advanced technologies to enhance user experience. The digital controller allows for easy monitoring and control of the generator's performance, providing crucial information such as voltage, frequency, and engine parameters in real-time. This feature helps operators stay informed of the system's status and facilitates timely maintenance when needed.

Safety is another critical consideration in the design of these generators. The DCA250SSI and DCA250SSIU include a comprehensive range of safety features, such as low oil pressure shutdown, high-temperature shutdown, and overcurrent protection, ensuring reliable operation while safeguarding against potential hazards.

Versatility is key with these models. They can be configured for both single-phase and three-phase output, catering to diverse energy requirements across different applications. Additionally, their compact design makes them easy to transport and install, further enhancing their appeal for rental companies and on-the-go operations.

In conclusion, the Multiquip DCA250SSI and DCA250SSIU stand out in the generator market with their blend of power output, fuel efficiency, noise reduction, and advanced technologies. Their robust design and safety features make them a reliable choice for a wide array of industries, offering peace of mind and consistent energy wherever it's needed.