General Information

Generator

This MQ Power generator (Figure 3) is a high quality portable (requires a trailer for transport) power source for telecom sites, lighting facilities, power tools, submersible pumps and other industrial and construction machinery.

engine control Panel

The “Engine Operating Panel” is provided with the following: „„Engine Warning Lamp Module

Oil Pressure Alarm Lamp

Water Temperature Lamp

Charging Alarm Lamp

Pre-Heat Lamp

„„Fuel Gauge

„„Hour Meter

„„Speed Control Switch

„„Ignition Switch

generator Control Panel

The “Generator Control Panel” is provided with the following: „„Frequency Meter (Hz)

„„AC Ammeter (Amps)

„„AC Voltmeter (Volts)

„„Ammeter Change-Over Switch „„Voltage Regulator

„„3-Pole, 100 amp Main Circuit Breaker

„„“Control Box” (located behind the Gen. Control Panel)

Automatic Voltage Regulator

Current Transformer

Over-Current Relay

Starter Relay

Voltage Selector Switch

Output Terminal Panel

The “Output Terminal Panel” is provided with the following: „„Two 250 VAC output receptacles (CS-6369), 50 amps „„Two auxiliary circuit breakers, 250V @50 amps „„Two 125 VAC output receptacles, (GFCI), 20 amps „„Two GFCI circuit breakers, 125V@ 20 amps „„Five output terminal lugs (3Ø power)

Options

„„Battery Charger

„„Water Heater

„„Low Coolant Level Switch/Indicator

„„Camlock Connectors

Open Delta Excitation System

This generator is equipped with the state of the art “Open- Delta” excitation system. The open delta system consist of an electrically independent winding wound among stationary windings of the AC output section.

There are four connections of the open delta A, B, C and D. During steady state loads, the power from the voltage regulator is supplied from the parallel connections of A to B, A to D, and C to D. These three phases of the voltage input to the voltage regulator are then rectified and are the excitation current for the exciter section.

When a heavy load, such as a motor starting or a short circuit occurs, the automatic voltage regulator (AVR) switches the configuration of the open delta to the series connection of B to C. This has the effect of adding the voltages of each phase to provide higher excitation to the exciter section and thus better voltage response during the application of heavy loads.

The connections of the AVR to the AC output windings are for sensing only. No power is required from these windings.

The open-delta design provides virtually unlimited excitation current, offering maximum motor starting capabilities. The excitation does not have a “fixed ceiling” and responds according the demands of the required load.

Engine

This generator unit incorporates an Kubota V3800-DI-T-E3B diesel engine. This engine is designed to meet every performance requirement for the generator. Reference Table 2 for engine specifications.

In keeping with MQ Power’s policy of constantly improving its products, the specifications quoted herein are subject to change without prior notice.

Electric Governor System (OPTION)

The electric governor system controls the RPMs of the engine. When the engine demand increases or decreases, the governor system regulates the frequency variation to ±.25%.

Extension Cables

When electric power is to be provided to various tools or loads at some distance from the generator, extension cords are normally used. Cables should be sized to allow for distance in length and amperage so that the voltage drop between the generator and point of use (load) is held to a minimum. Use the cable selection chart (Table 6) as a guide for selecting proper extension cable size.