Multiquip DCA40SSKU4i manual Place the engine speed control switch in the RUN position up

Models: DCA40SSKU DCA40SSKU4i

1 78
Download 78 pages 40.88 Kb
Page 33
Image 33

GENERATOR START-UP PROCEDURE

2.Depending on the temperature of the coolant (cold weather conditions), the pre-heat lamp (Figure 41) will light (ON) and remain on until the pre-heating cycle has been completed. After completion of the pre-heating cycle, the light will go OFF and the engine can be started

6.The generator’s frequency meter (Figure 44) should be displaying the 60 cycle output frequency in HERTZ.

Figure 41. Pre-Heat Lamp

3.Turn the ignition key to the start position (Figure 42). Once the engine starts, release the ignition key and allow it to return to the RUN position (Figure 40).

If the engine fails to start after 10 seconds, wait approximately 30 seconds and repeat steps 3-4.

Figure 44. Frequency Meter

7.The generator’s AC-voltmeter(Figure 45) will display the generator’s output in VOLTS..

Figure 42. Ignition Switch (Start Position)

4.Let the engine run for 1-2 minutes. Listen for any abnormal noises. If any abnormalities exist, shut down the engine and correct the problem.

5.Place the engine speed control switch (Figure 43) in the RUN position (up).

RUN

Figure 43. Engine Speed Control Switch

Run Position

Figure 45. Voltmeter Meter

8.If the voltage is not within the specified tolerance use the voltage adjustment control knob (Figure 46) to increase or decrease the desired voltage.

Figure 46. Voltage Adjust Control Knob

9.The ammeter (Figure 47) will indicate zero amps with no load applied. When a load is applied, the ammeter will indicate the amount of current that the load is drawing from the generator.

Figure 47. Ammeter (No Load)

DCA40sskU/ku4i 60 hz Generator • operation and parts manual — rev. #1 (03/11/13) — page 33

Page 33
Image 33
Multiquip DCA40SSKU4i manual Place the engine speed control switch in the RUN position up