GA-4.5R/GA-4.5RA — SPECIFICATIONS

 

 

GA-4.5R/GA-4.5RA — SPECIFICATIONS

 

 

 

 

 

 

 

Table 1. Specifications

 

 

 

 

 

 

 

 

MODEL

GA-4.5R/GA-4.5RA

 

 

 

 

 

 

 

 

Type

2-Pole, Brushless Type Revolving Field

 

 

 

 

 

 

 

 

Frequency (Hz)

60

 

 

 

 

 

 

 

 

Continuous Output (kW)

3.70

 

 

 

 

 

 

 

 

Maximum Output (kW)

4.5

 

 

 

 

 

 

 

 

Voltages (VAC)

120/240

 

 

 

 

 

 

 

 

Max/Continuous Amps 120 VAC

37.5/30.8

 

 

GENERATOR

 

 

 

 

Max/Continuous Amps 240 VAC

18.75/15.4

 

 

 

 

 

 

 

 

 

 

 

Rated Speed (RPM)

3600

 

 

 

 

 

 

 

 

Power Factor

1.0

 

 

 

 

 

 

 

 

Dimension (L x W x H) in. (mm)

23 X 18.5 X 20.25

 

 

 

(595 X 470 X 515)

 

 

 

 

 

 

 

 

 

 

 

 

Dry Net Weight lbs. (kg)

149 (68)

 

 

 

Includes Engine

 

 

 

 

 

 

 

 

 

 

 

 

Model (Engine Specification)

ROBIN EX27OD20110 (GA-4.5R)

 

 

 

ROBIN EX27OD20220 (GA-4.5RA)

 

 

 

 

 

 

 

 

 

 

 

 

Type

Air-cooled, 4-stroke, Single Cylinder, Overhead

 

 

 

Camshaft, Gasoline Engine

 

 

 

 

 

 

 

 

 

 

 

 

Displacement (cc)

265

 

 

 

 

 

 

 

 

Continuous Output (kW/min)

5.1 @3600

 

 

 

 

 

 

 

 

Maximum Output (kW/min)

9.0 @4000

 

 

 

 

 

 

 

ENGINE

Fuel Tank Capacity Gal. (L)

4.2 (19)

 

 

 

 

 

 

 

Fuel

Non-leaded Automobile Gasoline

 

 

 

 

 

 

 

 

Lube Oil Capacity Qts. (L)

1.16 (1.1)

 

 

 

 

 

 

 

 

Speed Control Method

Centrifugal Fly-weight Type

 

 

 

 

 

 

 

 

Starting Method

Recoil Start

 

 

 

 

 

 

 

 

Dimension (L x W x H) in. (mm)

13.97 X 16.5 X 16.14

 

 

 

(355 X 420 X 410)

 

 

 

 

 

 

 

 

 

 

 

 

Dry Net Weight lbs. (kg)

46.3 (21)

 

 

 

 

 

 

Effects of Altitude and Heat

The maximum output of the engine listed above is applicable to supplying electrical power for continuous service at ambient conditions in accordance with SAE Test cord J607. The above ambient conditions are at standard sea level, with a barometric reading of 29.92 inches and a temperature of 60 degrees fahrenheit.

Generally, the engine output power will decrease 3 1/2% for each 1000 feet of altitude above sea level, and 1% for each 10° F fahrenheit above the standard temperature of 60° F