13.Refer to the AC voltmeter (Figure 19) on the control box. The voltage indicated on the voltmeter should be 240 VAC with no load applied. If desired, verify with a voltmeter that 240V is present at the NEMA L14-20R twist-lock receptacle. In addition verify that 120VAC is present at the NEMA 5-20R GFCI duplex receptacle and the two NEMA L5-20R, L5-30R twist-lock receptacles.

3.Place the main circuit breaker (Figure 21) in the ON position.

Figure 21. Main Circuit Breaker (ON)

Stopping The Engine

Normal Shutdown

1.Place the main circuit breaker (Figure 9) in the OFF position.

2.Remove the load from the generator.

3.Place the idle control switch (Figure 22) in the up position (ON), and let the engine run at idle (2200 RPM's) for 3-5 minutes.

Figure 19. 240/120 VAC Receptacle

Figure 22. Idle Control Switch (2200 rpm's)

When the full power switch is

NOTE in the 240V (down) position, up to half of the rated power of the

generator is available at the 120V GFCI duplex receptacle, L5-20R and L5-30R twist-lock

receptacles; or full rated power can be obtained at the L14-20R (240V) receptacle. Rembmber, when using a combination of dual receptacles, total load should not exceed the rated capacity of the generator.

Connecting the Load

1.Connect the load to the desired voltage output receptacle.

2.Place the idle control switch (Figure 20) in the ON position (Up).

Figure 20. Idle Control Switch (Up)

4.Place the operation switch (Figure 23) in the STOP position.

Figure 23. Operation Switch (Stop)

5.Place the engine fuel valve lever (Figure 24) to the "OFF" position.

Figure 24. Engine Fuel Valve Lever (OFF Position)

Emergency Showdown

1.Place the operation switch (Figure 23) in the STOP position.

GA-4.5R/GA-4.5RA A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #1 (11/27/06) — PAGE 25