GA-4.5R/GA-4.5RA — MAINTENANCE (ENGINE)

Maintenance

Perform the scheduled maintenance procedures as defined by Table 6 and below:

DAILY

Thoroughly remove dirt and oil from the engine and control area.Clean or replace the air cleaner elements as necessary. Check and retighten all fasteners as necessary. Check the gearbox for oil leaks. Repair or replace as needed.

WEEKLY

Remove the fuel filter cap and clean the inside of the fuel tank.

Remove or clean the filter at the bottom of the tank.

Remove and clean the spark plug (Figure 25), then adjust the spark gap to 0.024 ~0.028 inch (0.6~0.7 mm).This unit has electronic ignition, which requires no adjustments.

Figure 25. Spark Plug Gap

ENGINE OIL

1.Drain the engine oil when the oil is warm as shown in Figure 26.

2.Remove the oil drain bolt and sealing washer and allow the oil to drain into a suitable container.

3.Replace engine oil with recommended type oil as listed in Table 4. For engine oil capacity, see Table 1 (engine specifications). DO NOT overfill.

4.Install drain bolt with sealing washer and tighten se- curely.

Cleaning the Fuel Strainer

Clean the fuel strainer if it contains dust or water. Remove dust or water in the strainer cap and wash it in gasoline. Securely fasten the fuel strainer cap so that fuel will not leak. Check the fuel strainer every 200 hours of operation or once a month.

DANGER - EXPLOSIVE FUEL

DO NOT use gasoline as a cleaning solvent, because that would create a risk of fire or explosion.

ENGINEAIRCLEANER

1.Remove the air cleaner cover and foam filter element as shown in Figure 27.

2.Tap the paper filter element (Figure 27) several times on a hard surface to remove dirt, or blow compressed air [not exceeding 30 psi (207 kPa, 2.1 kgf/cm2)] through the filter elementfromtheaircleanercaseside.NEVER brushoffdirt. Brushingwillforcedirtintothefibers.Replacethepaperfilter element if it is excessively dirty.

Figure 27. Engine Air Cleaner

Figure 26. Engine Oil (Draining)

PAGE 28 — GA-4.5R/GA-4.5RA A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #1 (11/27/06)

Page 28
Image 28
Multiquip GA4.5RA manual Spark Plug Gap, Engine Air Cleaner

GA4.5RA, GA4.5R specifications

The Multiquip GA4.5R and GA4.5RA are advanced generators designed for professionals who require reliable power sources across various applications. Engineered with cutting-edge technologies, these models stand out in the competitive generator market.

One of the key features of the GA4.5R and GA4.5RA is their robust power output. Both models are capable of delivering 4.5 kW of continuous power, making them suitable for a range of applications from construction sites to outdoor events and emergency backup. This reliable output is coupled with a reputable eco-friendly engine that minimizes fuel consumption while providing consistent power.

The design of the GA4.5R and GA4.5RA generators emphasizes ease of use and portability. With a compact and lightweight structure, these generators can be easily transported, making them ideal for users on the go. A user-friendly control panel enhances operational convenience, allowing users to monitor performance metrics such as voltage and frequency effortlessly.

In terms of durability, Multiquip has ensured that both models are built with high-quality materials that can withstand demanding conditions. The sturdy frame offers protection against falls and impacts, while the weather-resistant housing protects internal components from external elements. This rugged design guarantees longevity, making these generators a solid investment for users.

The GA4.5RA model introduces advanced technology with its electric start feature, adding even more convenience for users. This eliminates the need for manual recoil starting, making the generator easy to operate, especially in low-light conditions or for those who may have difficulty with traditional starting methods.

Additional safety features are integrated into both models, including low oil shutdown and circuit breaker protection, ensuring that the generator operates securely and efficiently. This attention to safety appeals to professionals who rely on their equipment to perform at optimal functionality without compromising user safety.

To summarize, the Multiquip GA4.5R and GA4.5RA generators are designed with power, portability, and durability in mind. Their advanced features and technologies cater to a variety of applications, making them an invaluable tool for anyone in need of reliable power solutions. With Multiquip's reputation for quality and performance, these models are poised to meet the demanding expectations of users across different industries.