gb12bw/bs/bp LIgHTINg sYsTeM • operaTIoN aNd parTs MaNuaL — rev. #0 (06/24/13) — page 29

FILTer repLaCeMeNT

1. Remove the balloon as described in the STORAGE
section.
2. Turn the balloon/lamp assembly upsidedown to access
the filter. See Figure 45.
Figure 45. Accessing Filter
3. Turn the three locking tabs outwards to release the air
plate. See Figure 45.
4. Remove the air plate and filter. See Figure 46.
Figure 46. Filter Removal
5. Install a new filter and reinstall the air plate.
AIR PLATE
LOCKING
TAB
AIR PLATE
FILTER
maintenanCe
6. Turn the three locking tabs inwards to lock the air plate
in place. See Figure 47.
Figure 47. Locking Air Plate
LOCK TAB