gb12bw/bs/bp LIgHTINg sYsTeM • operaTIoN aNd parTs MaNuaL — rev. #0 (06/24/13) — page 21
oPeration (Gb12bW)

appLYINg power (gb12bw)

1. Before applying power, make sure that the Power
oN/oFF switch (Figure 16) is in the OFF position.
Figure 16. ON/OFF Switch
2. Connect the AC power cable to the 120 VAC receptacle
on the generator used. See Figure 17.
Figure 17. Connecting to Power Source
3. Start the generator as indicated in the generator
manual.
4. Turn on the Power oN/oFF switch (Figure 16). The
balloon will start to inflate and the lamp will turn on.

dIMMINg THe LaMp

1. Slightly unzip the bottom of the balloon to gain access
to the dimmer switch (Figure 18).
Figure 18. Unzipping Balloon
01
POWER
ON/OFF
SWITCH
20A
120V
120 VAC
RECEPT
ACLE
POWE
R
CABLE
TYPICAL
GENERATOR
FRONT P
ANEL
ZIPPER
BALLOON
2. Press the dimmer switch lightly (Figure 19). The LED
will blink. The lamp should dim to about 75% brightness.
Figure 19. Dimmer Switch
3. To turn back the lamp to its original brightness, press
the dimmer switch again. The LED will turn off.
4. Tor turn off the lamp while keeping the balloon inflated,
press and hold the dimmer switch for three seconds.
The LED will light red.
5. Zip up the bottom of the balloon completely after use
of the dimmer switch.

sHuTdowN

1. Turn off the power switch of the generator.
2. Turn off the Power oN/oFF switch. The balloon should
start to deflate and the lamp will turn off.
3. Disconnect the AC power cable from the generator.
01
DIMMER
SWITCH
NOTICE
To turn on lamp again, after it was turned off with the
dimmer switch, turn off the Power oN/oFF switch. Wait
three to five minutes then turn the oN/oFF switch back
on. The lamp will now light back to 100% brightness.
NOTICE
If the power cable is accidentally unplugged from
the power source, wait three to five minutes before
reconnecting the power. This will allow time for the fan
to reset and ensure balloon will inflate properly when
power is reconnected.
CauTIoN
Allow a sufficient amount of time (15-20 minutes) for the
lamp to cool down. The possibility exists of the balloon
getting burned (touching the lamp).