Multiquip GBP5000H manual GDP-5000H - PRE-SETUP, Lubrication Oil, Fuel

Models: GBP5000H

1 76
Download 76 pages 19.3 Kb
Page 13
Image 13
Lubrication Oil

Lubrication Oil

Fill the engine crankcase with lubricating oil through the filler hole, but do not overfill. Make sure the generator is level. With the dipstick inserted all the way, but without being screwed into the filler hole, verify that the oil level is maintained between the two notches on the dipstick.

The oil listed in Table 4 is recommended to ensure better engine performance. Use class SC or higher grade motor oil.

Table 4. Recommended Motor Oil

Temperature

Type Oil

Range

 

 

 

104° F ~ 23° F

SAE 30

(40° C ~ -5°C)

 

 

 

23° F ~ 5° F

SAE 20 or sae 10W-30

(-5° C ~ -15°C)

 

 

 

Below 5° C (-15°)

SAE 10W or SAE 10W-30

 

 

GDP-5000HPRE-SETUP

Fuel

Close the fuel cock before filling the tank. Fill the fuel tank with clean and fresh unleaded gasoline. Do not fill the tank beyond capacity.

Pay attention to the fuel tank capacity when replenishing fuel. Refer to the fuel tank capacity listed on page 8 Specification Table 1.

The fuel tank cap must be closed tightly after filling.

Handle fuel in a safety container. If the container does not have a spout, use a funnel.

CAUTION :

Never fill the fuel tank while the engine is running or in the dark. Gasoline spillage on a hot engine can cause a fire or explosion. If gasoline spillage occurs, wipe up the spilled gasoline completely to prevent fire hazards.

GDP-5000H A.C. GENERATOR — OPERATION AND PARTS MANUAL — REV. #2 (07/23/08) — PAGE 13

Page 13
Image 13
Multiquip GBP5000H GDP-5000H - PRE-SETUP, Lubrication Oil, Fuel, The fuel tank cap must be closed tightly after filling