PS7060 MULTIQUIP SAW — MAINTENANCE

MAINTENANCE

WARNING

Certain maintenance operations or machine adjustments require specialized knowledge and skill. Attempting to perform maintenance operations or adjustments without the proper knowledge, skills or training could result in equipment damage or injury to personnel. If in doubt, consult your dealer.

When performing maintenance operations on the saw or engine, follow all safety messages and rules for safe operation stated here and

at the beginning of this manual.

See the engine manufacturer's manual supplied with your machine for appropriate

maintenance schedule and troubleshooting guide for problems.

WARNING

Accidental starts can cause severe injury or death!

ALWAYS place the ON/OFF switch in the OFF position.

Disconnect negative battery cable from battery before servicing.

Engine and muffler surfaces can get

HOT! Allow to cool before servicing.

ALWAYS ensure saw is SECURELY placed on appropriate blocks or jackstands when performing maintenance requiring the saw to be elevated.

CAUTION

Avoid slips and falls!

Clean up all engine oil, hydraulic oil, and diesel fuel spills immediately.

Maintenance Schedule

Daily (8-10 Hours)

1.Check fluid levels in engine and reservoir; fill as necessary.

2.Visually inspect for wear and damage.

3.Visually inspect for engine leaks.

4.Check or replace the engine air filters as necessary.

5.Check operation of Emergency Stop Button.

Monthly (125-150 Hours)

1.Change Hydraulic oil and filter.(First 125 hours, then every 250 hours.)

2.Change Engine oil and filter.

Yearly (500-600 Hours)

1.Replace fuel filter cartridge and v-belt.

2.Check fuel lines for leakage.

3.Check battery cables and connectors.

4.Check engine monitoring and warning system.

Air Cleaners (Daily)

The saw utilizes both a primary air filter and a safety air filter, (Figure 40).The air filter restriction light, (Item A, Figure 39) on the engine status indicator (Item B, Figure 39), will illuminate when the filter is plugged.

A

B

Figure 39. Air Filter Restriction Light

Empty the dust discharge valve daily and clean the discharge slot from time to time. (Figure 40)

While the air filters should be checked daily and replaced when necessary, there is no need to "over-service" the air filters.That is, they require no cleaning and do not require the use of oil. If the primary filter becomes clogged, simply replace it.

PS7060 MULTIQUIP SAW • OPERATION MANUAL — REV. #2 (06/02/08) — PAGE 39

Page 39
Image 39
Multiquip PS706016, PS706026 PS706030, PS706020, PS706036 operation manual PS7060 Multiquip SAW Maintenance

PS706020, PS706036, PS706026 PS706030, PS706016 specifications

The Multiquip PS706026, PS706030, PS706036, and PS706020 are highly regarded in the world of portable generators, designed to offer optimum performance and reliability for various applications. These models showcase a blend of advanced technologies and user-friendly features, catering to both professional and residential needs.

One of the standout features of the Multiquip PS706 series is their robust and efficient engines, which deliver reliable power output. These generators are equipped with a powerful Honda engine, ensuring superior performance even in demanding conditions. The engines are designed to be fuel-efficient, allowing users to save on fuel costs while maximizing operational time.

Another significant aspect of the PS706 series is their electric start capability. This feature offers added convenience, enabling users to start the generator at the push of a button. Additionally, the generators are equipped with a recoil backup starter, ensuring that users have a reliable starting method in the event of an electrical failure.

The generators are built with a heavy-duty frame and are designed to withstand tough job site conditions. Their compact and portable design allows for easy transportation, making them an excellent choice for contractors, construction sites, and recreational use. The inclusion of rugged wheels and a comfortable handle ensures that moving the generator is hassle-free.

Moreover, the PS706 series showcases impressive noise-reduction technology. With a well-designed muffler system, these generators operate quietly, making them suitable for use in residential areas and during outdoor events where noise restrictions may apply.

Safety features are also paramount in the Multiquip PS706 series. They are equipped with circuit breakers to prevent overload and automatic low-oil shutdown to protect the engine from damage. This focus on safety ensures that users can operate the generators with peace of mind.

The PS706 series generators have multiple outlet options, providing versatility in power supply. Users can charge multiple devices simultaneously, thanks to the inclusion of 120V/240V receptacles and GFCI-protected outlets.

In summary, the Multiquip PS706026, PS706030, PS706036, and PS706020 generators are engineered with high-performance engines, easy starting options, and advanced safety features. Their durability, portability, and noise-reduction capabilities make them suitable for a wide range of applications, from construction to home backup power. With these models, users can expect reliable and efficient performance even in the most demanding environments.