Multiquip PS706026 PS706030, PS706020, PS706036, PS706016 Raise-Lower System Troubleshooting

Models: PS706020 PS706036 PS706026 PS706030 PS706016

1 66
Download 66 pages 56.09 Kb
Page 52
Image 52

PS7060 MULTIQUIP SAW — MAINTENANCE

42

7

5

3

6

1

1.Pump Motor

2.Lift Pump Reservoir

3.Raise-LowerValve (Solenoid)

4.Raise-Lower Toggle

5.Raise-Lower Wire Harness

6.Lift Cylinder

7.Lift Pump Solenoid

Figure 64. Raise-Lower System

Raise-Lower System Troubleshooting

Refer to the following table to assist in troubleshooting the Raise-

Lower System.

Table 10. Raise-Lower System Troubleshooting

Indication

Possible Causes

 

 

Won't Raise

battery discharged, raise-lower solenoid faulty, cables

loose or damaged, defective wiring

 

Won't Lower

switch bad, faulty wiring connection, coil bad, valve

cartridge bad

 

PAGE 52 — PS7060 MULTIQUIP SAW • OPERATION MANUAL — REV. #2 (06/02/08)