Multiquip PS706016 Remove the oil reservoir cap to speed oil draining, Long Term Storage

Models: PS706020 PS706036 PS706026 PS706030 PS706016

1 66
Download 66 pages 56.09 Kb
Page 55
Image 55

PS7060 MULTIQUIP SAW — MAINTENANCE

TipsWhen Draining and Filling the Hydraulic Oil System

1.Itwilltake3-4quartstofillthehydraulicsystemwhennew,and somewhat less when changing the oil.

2.Remove the oil reservoir cap to speed oil draining.

3.When re-filling the system, raise the saw halfway up, then lift the rear of the saw until the Blade Flanges touch the ground. This will help to speed the filling process.

4.After filling the system, jack the saw up so the drive wheels are off the ground. Start the saw and move the Control Handle half way into FORWARD to purge air out of the system.

If the Blade Shaft is drained completely, it will require approximately 1 gallon to refill.

Stay-Level Handles (SLH)

The Stay-Level Handlebar system is designed to require very little maintenance. (See Figure 69. below)

NEVER try to lift the saw with the handlebars (a lift bale is provided for lifting). DO NOT try to dislodge a stuck blade by prying or using excessive force on the handlebars.

Long Term Storage

Remove the battery.

Drain fuel from fuel tank and fuel lines.

Clean exterior with a cloth soaked in clean oil.

Store unit covered with plastic sheet in moisture and dust- free location out of direct sunlight.

CAUTION

Never store the saw with fuel in the tank for any extended period of time. Always clean up spilled fuel immediately.

Decommissioning Saw/Components

Decommissioning is a controlled process used to safely retire a pieceofequipmentthatisnolongerserviceable. Iftheequipment poses an unacceptable and unrepairable safety risk due to wear or damage or is no longer cost effective to maintain, (beyond life- cycle reliability) and is to be decommissioned, (demolition and dismantlement), the following procedure must take place:

1.Drain all fluids completely. These may include oil, gasoline, hydraulic oil and antifreeze. Dispose of properly in accor- dance with local and governmental regulations. Never pour on ground or dump down drains or sewers.

2.Remove battery and bring to appropriate facility for lead reclamation. Use safety precautions when handling batter- ies that contain sulfuric acid, (See page 16).

3.The remainder can be brought to a salvage yard or metal reclamation facility for further dismantling.

Figure 69. Stay Level Handlebar System

PS7060 MULTIQUIP SAW • OPERATION MANUAL — REV. #2 (06/02/08) — PAGE 55