Start Stop
min. 2 m3.5 Safety and monitoring equipment
3.5.1 Shut down yoke
The shutdown yoke is attached to the rear of the machine below the operating unit.
At the rear end below the mounting of the shutdown yoke is a proximity switch. The
shutdown yoke is activated and the proximity switch triggers, if the machine drives
against an obstacle. It thereupon sends a signal to the machine controller and the
machine can only be driven away from the obstacle in a forward direction. An
active vibration function is switched off. The vibration function must be manually
activated again after deactivation of the shutdown yoke. The shutdown yoke must
be fastened with the transport strap during transport (transport position).
3.5.2 Low distance shutdown (only with infrared control)
The low distance shutdown function is accommodated in the machine controller.
The engine continues to run, however all driving functions are deactivated, if the
minimum distance between transmitter and receiver is less than 2 meters. The
driving functions are available again, as soon as the minimum distance has been
attained again.
3.5.3 Far distance shutdown (only with infrared control)
The far distance shutdown function is accommodated in the machine controller.
The maximum distance between transmitter and receiver depends on the
weather and is between 20 and 24 meters. The engine continues to run, however
all driving functions are deactivated, if the maximum distance is exceeded. The
driving functions are available again, as soon as the distance is less than the
maximum distance.