RX 1510-C/-I/-CI
– 70 –
F 4200
F 4 I00
0
F 43005.4 Switching machine off
5.4.1 Switching the machine off at the ignition lock
► Turn the ignition key to position "0". The following code is displayed: „F 4100”.
The LEDS for generator and oil pressure drop are active. The stop procedure
is initiated.
Stop procedure
► Code „F 4200” is displayed, if no further signal is received from the generator
and from the oil pressure sensor.
► End of the stop procedure. „F 4300” is displayed. The operating hour meter
is saved. The machine shuts down. Restarting is only possible after the end of
this stop sequence.
Remove the key after finishing work and secure the machine against
unauthorized use.
Start-up