Programming Example:

PROGRAMMING (OPTIONAL)

Programming Example:

Program the User 3 Code to “3784”:

1.Select the Program Mode as follows:

(a)Enter your User Code, followed by R.

(b)Answer NO (press Q) repeatedly until “TurnOn

Prog Yes/No” is displayed, then press YES (P).

The display will briefly read: “UPXXXX” then "User01" (User 1's Code).

2.Press 03for User No. 3.

3.Press Rto advance to the User Code screen.

4.Press 3784to program the code. If any other digits are left over from a previous User-3 Code, delete each by pressing G0.

Note: Do not attempt to program the "OPTion" or "ACCess" screens (if they display) as they will not be saved.

5.Press Uto save the code.

6.Press Cto exit the Program Mode.

Notes:

Note: Duplicate Codes are not allowed; therefore a dupli-

cate Code entered in the LCD Window will erase when Uis pressed.

If the system contains more than one keypad, only the keypad designated “No. 1” may be used for programming (if in doubt which is No. 1, ask your installer).

While in Program Mode, the ARMED and STATUS lights remain off and burglar and fire alarm functions are disabled.

In selecting your codes, do not program repetitive numbers (1111), consecutive numbers (1234), your birth date, address, or other obvious combinations. Choose a code of up to six digits (a minimum of four is recommended, and required in UL installations). If the keypad detects no Program Mode activity for more than 4 minutes, a tone will sound. Press Cto silence.