KEYPAD MESSAGES

 

CAN'T/

A C O N

ARMZNF

 

 

 

 

 

CAN'T/

A C O N

ARMSIL

 

 

 

 

 

CAN'T/

A C O N

ARMSND

 

 

 

 

 

CAN'T/

A C O N

ARMRST

 

 

 

 

 

DAY ZN

A C O N

 

 

 

 

 

 

ALARM

A C O N

 

 

 

 

 

T R O U B L E

CANCEL

 

A C O N

 

 

 

Arming attempted with zone in trouble. Faulted zones will scroll. Correct trouble to arm.

Arming attempted while the alarm is sounding. A valid user code will silence the sound and clear this message.

Attempted to arm with Easy Arm and the alarm is sounding. The alarm wit not silence without a valid user code.

Arming attempted with a system trouble present. To arm, press Cand the system troubles will disappear.

(With pulsing sounder). Trouble condition on a Day Zone (zone numbers will scroll). Press Cto silence sounder. Note: Watch Mode must be active.

Alarm Condition, followed by zone number(s). "ALARM" and zones will display after sys- tem is disarmed. Note zones, then press Cto clear keypad.

The alarm signal has been cancelled during the Abort Delay (before an alarm signal re- port was sent to the central station). If cancelled after the alarm signal report was sent, this message appears when the system receives an acknowledgment from the central station of the cancellation of the alarm signal.