KEYPAD MESSAGES

T R O U B L E

SYSTBL

 

A C O N

 

 

 

 

 

T R O U B L E

E01-00/

 

A C O N

ACFAIL

 

 

T R O U B L E

E02-00/

 

A C O N

LOBATT

 

 

T R O U B L E

E03-00/

 

A C O N

COMMFL

 

 

T R O U B L E

E06-01

 

A C O N

 

 

 

 

 

 

OV(RR)

A C O N

 

 

 

 

 

 

EntNow

A C O N

 

 

 

Indicates problem(s) detected on the system (see below).

Check power transformer. Check for blown fuse or circuit breaker; general power outage.

Battery weak. If not recharged within 24 hours, replace battery.

Communication failure to central station.

(Wireless systems only). Receiver response failure, Receiver No. 1. The following addi- tional wireless messages may also appear:

“E04-01” - Supervisory trouble on Zone 1 (transmitter has not “checked in”). “E05-01” - Transmitter on Zone 1 has a low battery;

“E15-01” - Transmitter on Zone 1 has its case open (tamper condition);

(OPTIONAL) (Commercial Systems Only). Overview Mode. Simultaneously shows status of Areas 1 and 2. “R” Area Ready; “Z” Zone Fault; ‘A” = Area Armed; “B” = Bur- glary Zone in Alarm; “F” = Fire Zone in Alarm; “T” = Fire Trouble; "c" = Check Trouble; Area in Function-Display Mode.

(Commercial Systems Only). Remote-access keypad unlocked for 5 seconds to allow entry.

31

Page 31
Image 31
Napco Security Technologies GEM-K2AS manual Acfail, Lobatt, Commfl, Ovrr