9￿System Troubles

ARMED

READY

SYSTEM

ZONE 1

ZONE 2

ZONE 3

ZONE 4

12

The XP400 is constantly monitoring its own components, as well as all critical services, such as AC Power and the Telephone line, to insure that it is always ready to provide the protection for which it was designed. When a system trouble does occur, it will caution you by lighting the Yellow SYSTEM light and beeping the keypad buzzer. If you cannot immediately clear the system trouble, the system can still be used. Simply

press

to view the trouble as described below, and then arm the system.

In order to determine the nature of the trouble, press

, count the number of keypad beeps and observe

the number of the illuminated zone light. Refer to the following table to determine the cause of the trouble.

If there is more than one trouble to be viewed, pressing

will scroll to the next, and then exit the

SYSTEM mode if there are no additional troubles to view.

Keypad Beeps or

Zone light

System Trouble

 

Action

SYSTEM Flashes

ON

Condition

 

 

 

 

 

 

1 Beep

1

AC Power Failure

This trouble will occur if AC power is not present. Make sure

 

 

 

system transformer is plugged into AC receptacle and check

 

 

 

circuit breaker, otherwise call installing company for service.

 

 

 

 

1 Beep

2

Low Battery

If there has been a recent power failure, the battery may be

 

 

 

partially depleted and must be recharged by the control

 

 

 

panel. If the trouble does not go away in 24 hours, call in-

 

 

 

stalling company for service.

 

 

 

 

1 Beep

3

Communication

The system was not able to report to central station. If this is

 

 

Failure

due to a temporary interruption in the telephone service, the

 

 

 

trouble can be cleared when the service is restored by press-

 

 

 

ing

. Otherwise, call installing company for service.

 

 

 

 

1 Beep

4

Telephone Line Cut

The telephone line has failed. If telephone service has been

 

 

 

temporarily interrupted, the trouble will clear it is when re-

 

 

 

stored. Otherwise, call installing company for service.

 

 

 

 

 

Oi220a

Tuesday, September 16, 1997 08:30

page 12

 

Page 12
Image 12
Napco Security Technologies XP-400 manual 9System Troubles, System Flashes

XP-400 specifications

Napco Security Technologies has established itself as a leading name in the field of security solutions, and one of its standout products is the XP-400, a cutting-edge alarm panel designed for modern security applications.

The Napco XP-400 is recognized for its robust performance and versatility, making it suitable for both residential and commercial security systems. At the heart of its design is an advanced microprocessor that ensures seamless operation and efficient processing of security signals. This intelligent technology allows for faster response times and greater reliability compared to traditional panels.

One of the main features of the XP-400 is its ability to support a wide array of devices. It can accommodate a variety of sensors, keypads, and other peripherals, enabling users to customize their security systems to meet specific needs. The panel supports both hardwired and wireless devices, providing flexibility in installation and enhancing the overall adaptability of the security system.

Security is further enhanced through the XP-400's integration with Napco's proprietary technologies. The panel features built-in alarm verification, which significantly reduces false alarms by allowing for the confirmation of intrusion events before dispatching emergency services. This feature is critical for maintaining a good relationship with local authorities and ensures efficient utilization of resources.

Moreover, the XP-400 utilizes advanced communication technologies, supporting various forms of connectivity, including phone line, cellular, and internet-based connections. This multi-faceted communication strategy ensures that alerts and notifications are promptly delivered to users and monitoring centers, regardless of the circumstances.

In terms of user interface, the XP-400 is designed with ease of use in mind. The panel includes user-friendly keypads that allow for straightforward operation, programming, and user management. The intuitive layout ensures that even those with limited technical knowledge can navigate and manage their security system effectively.

Another notable characteristic of the XP-400 is its scalability. As security needs evolve, the panel can be expanded with additional zones and features, ensuring long-term viability and protection for its users. This scalability not only extends the life of the investment but also allows for future upgrades in response to changing security technologies and threat landscapes.

In conclusion, the Napco Security Technologies XP-400 stands out as a reliable and versatile security solution. With its advanced microprocessor, comprehensive device support, alarm verification, and flexible communication capabilities, it remains an excellent choice for those looking to enhance their security infrastructure. Its user-friendly design and scalability further solidify its reputation as a top-tier security panel on the market.