HORIZONTAL TERMINATION

when (HT) > (VT)

Simple venting configuration (only one 45º and 90° elbow)

FIGURE7

See graph to determine the re- quired vertical rise VT for the required horizontal run HT.

REQUIRED

VERTICAL

RISE IN

INCHES (VT)

HORIZONTAL VENT RUN PLUS OFFSETS IN FEET (HT)

The shaded area within the lines represents acceptable values for HT and VT .

For vent configurations requiring more than one 45º and 90° elbow the following formulas apply:

Formula 1: HT < 4.2 VT

Formula 2: HT + VT < 24.75 feet

Example 2:

 

 

 

 

90°

 

 

H4

FIGURE8

H3

 

 

 

 

 

 

 

 

 

 

 

 

45°

 

 

 

 

V1

 

 

H2

 

 

 

H1

 

 

 

90°

 

90°

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V1

= 4 ft

 

 

 

 

 

 

VT

= V1 = 4 ft

 

 

 

 

 

 

H1

= 2 ft

 

 

 

 

 

 

H2

= 1 ft

 

 

 

 

 

 

H3

= 1 ft

 

 

 

 

 

 

H4

= 1.5 ft

 

 

 

 

 

 

HR

= H1 + H2 + H3 + H4 = 2 + 1 + 1 + 1. 5 = 5.5 ft

HO

= .03(one 45º elbow + three 90º elbow -135º)

 

=.03(315-135)=5.4ft

 

 

 

 

 

 

HT

= HR + HO = 5.5 +5.4 = 10.9 ft

 

 

 

 

HT + VT

= 10.9 + 4 = 14.9 ft

 

 

 

 

 

 

Formula 1: HT < 4.2 VT

4.2VT = 4.2 x 4 = 16.8 ft

10.9< 16.8

Formula 2: HT + VT < 24.75 feet

14.9 < 24.75

Since both formulas are met, this vent configuration is ac- ceptable.