Napoleon Fireplaces BGD40-N Open-Endinstallation Procedure, Venting, Framing, Facing, Finishing

Models: BGD40-P BGD40-N

1 36
Download 36 pages 46.42 Kb
Page 16
Image 16
OPEN-END INSTALLATION PROCEDURE

16

OPEN-END INSTALLATION PROCEDURE

VENTING

Refer to pages 6-13. All venting must have a minimum clearance of 1" to combustible.

FRAMING

See Page 18 for additional framing dimensions. Note: In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the fireplace body, it is recommended that the walls of the fireplace enclosure be “finished” (ie: drywall/sheetrock), as you would finish any other outside wall of a home. This will ensure that clearance to combustibles is maintained within the cavity.

It is best to frame your fireplace after it is positioned and the vent system is installed. Use 2x4's and frame to local building codes.

FIGURE20

A

A = 25¼" minus finishing material thickness each side.

NOTE: LEFT CORNER UNIT ILLUSTRATED

To install the fireplace face flush with the finished wall, position the framework to accommodate the thickness of the finished wall.

BRICK PANEL INSTALLATION

Install the base panels as illustrated in steps 1-4 on page

15.The side panel sits under the bracket tab. Holding the side panel in position, bend down the tab to secure. DE- TAIL 6.

FIGURES21a-c

STEP 5

RETAINER

DETAIL6STEP 6

FACING

Combustible materials may be installed flush with the front of the fireplace but must not cover any of the black face- areas of the fireplace. Non-combustible material (brick, stone or ceramic tile) may protrude in these areas.

It is not necessary to install a hearth extension with this fireplace system.

When roughing in the fireplace, raise the fireplace to ac- commodate for the thickness of the finished floor materi- als, i.e. tile, carpeting, hard wood, which if not planned for will interfere with the opening of the lower access door and

the installation of many decorative flashing accessories.

Objects placed in front of the fireplace should be kept a minimum of 48" away from the glass front faces.

FINISHING

Refer to pages 22-25 for complete instructions regarding mantle requirements and installations, log placement, glass door and upper and lower louvre attachments.

FIGURE22

DRYWALL

DRYWALL

 

5" MIN

W415-0299/C/03.12.03

Page 16
Image 16
Napoleon Fireplaces BGD40-N Open-Endinstallation Procedure, Venting, Framing, Brick Panel Installation, Facing, Finishing