TROUBLE SHOOTING GUIDE
BEFORE ATTEMPTING TO TROUBLESHOOT, PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR OPEN.
SYMPTOM | PROBLEM | TEST SOLUTION |
|
|
|
Main burner flame Blockage in vent.
is a blue, lazy, |
| |
t r a n s p a r e n t | Incorrect installation. | |
flame. | ||
|
Flames are con- Unit is
or too small. Carboning occurs.
B A
OL
| N | O |
| F | |
HI | O | F |
| IP | |
|
| |
|
| TOL |
TOLIP
-remove blockage. In really cold conditions, ice buildup may occur on the terminal and should be removed as required.
-refer to Figure 34 to ensure correct location of storm collars. (vertical vent)
-check pressure readings:
Inlet pressure can be checked by turning screw (A)
Outlet pressure can be checked the same as above using screw (B). Gauge should read 3.5" water column for natural gas or 10" water column for propane. Check that main burner is operating on "HI".
AFTER TAKING PRESSURE READINGS, BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL. DO NOT OVERTORQUE.
Leak test with a soap and water solution.
Carbon is being deposited on glass, logs or c o m b u s t i o n chamber sur- faces.
Air shutter has become | - | ensure air shutter opening is free of lint or other obstructions. |
blocked |
|
|
|
|
|
Flame is impinging on the | - | check that the logs are correctly positioned. |
logs or combustion cham- | - | open air shutter to increase the primary air. |
ber. | - | check the input rate: check the manifold pressure and orifice size |
as specified by the rating plate values.
- check that the door gasketing is not broken or missing and that the seal is tight.
- check that both 5" and 8" vent liners are free of holes and well sealed at all joints.
- check that minimum rise per foor has been adhered to for any horizontal venting.
White / grey film | Sulphur from fuel is being | - clean the glass with a recommended gas fireplace glass cleaner. |
forms. | deposited on glass, logs or | Do not clean glass when hot! |
| combustion chamber sur- | If deposits are not cleaned off regularly, the glass may become per- |
| faces. | manently marked. |
Exhaust fumes | Fireplace is spilling. | - check door seal and relief flap seal. |
smelled in room, |
| - check for chimney blockage |
headaches. |
| - check that chimney is installed to building code. |
|
| - room is in negative pressure; increase fresh air supply. |
Pilot goes out when the gas knob is released.
The gas valve has an interlock de- vice which will not allow the pilot burner to be lit until the thermo-
couple has cooled. Allow ap- proximately 60 seconds for the thermocouple to cool.
System is not correctly | - | purge the gas line with a glass door open. | |
purged. |
|
|
|
|
|
|
|
Out of propane gas. | - | fill the tank. |
|
Pilot flame is not large | - | turn up the pilot flame. | |
enough |
|
|
|
Pilot flame is not engulfing | - | gently twist the pilot head to improve the flame pattern around the | |
the thermocouple. | thermocouple. | ||
Thermocouple shorting / | - | loosen and tighten thermocouple. | |
faulty. | - | clean thermocouple and valve connection. | |
| - | replace thermocouple. | |
| - | replace valve. | |
Faulty valve. | - | replace. |